INSTRUCTION REF: IN205
ISSUE NO. 3
DATE 07.03.12
Page 9 of 18
www.parry.co.uk
9
TECHNICAL DETAILS GGP6.4
Total Unit
GAS
OPERATING PRESSURE
TOTAL HEAT INPUT
NATURAL G20
20mb/8” W.G.
3.100 KW = 10578 Btu/h
BUTANE G30
29mb/11.2” W.G.
3.100 KW = 10578 Btu/h
PROPANE G31
37mb/14.8” W.G.
3.100 KW = 10578 Btu/h
G25
25mb/10” W.G.
2.900 KW = 9895 Btu/h
GAS RATE
M³/HR
FT³/HR
LB/HR
KG/HR
NATURAL G20
0.330 M³/HR 11.654 FT³/HR
BUTANE G30
0.101 M³/HR 3.564 FT³/HR
0.518 LB/HR 0.235 KG/HR
PROPANE G31
0.133 M³/HR 4.714 FT³/HR
0.518 LB/HR 0.235 KG/HR
G25 @ 25mb
0.350 M³/HR 12.360 FT³/HR
INJECTORS
Natural G20 = INJECT 125
Butane G30 = INJECT 93
Propane G31 = INJECT 93
G25 @ 25mb = INJECT 125