background image

 

 

INSTRUCTION REF: IN205 
ISSUE NO. 3 

DATE 07.03.12 
Page 2 of 18 

 

www.parry.co.uk 

 
 
SAFETY INSTRUCTIONS 
 
IMPORTANT, PLEASE READ INSTRUCTIONS FULLY BEFORE USE 
 
THIS APPLIANCE IS ONLY FOR PROFESSIONAL USE AND MUST ONLY BE 
USED BY QUALIFIED PEOPLE. 
 

Attention should be drawn to the fact that parts of this unit by necessity, will get 
VERY  HOT,  and  will  cause  burns  if  touched  accidentally.  Therefore  it  is  the 
responsibility of the supervisor or equivalent to provide SUITABLE PROTECTIVE 
CLOTHING for the user. 

 
THIS  APPLIANCE  MUST  BE  FITTED  AND  TESTED  BY  A  REGISTERED 
FITTER BEFORE USE. 
 

The  unit  should  be  installed  in  compliance  with  the  INSTALLATION 
INSTRUCTIONS  and  the  NATIONAL  REGULATIONS  in  force  at  the  time. 
Particular  attention  should  be  paid  to  the  Gas  Safety  (Installation  and  Use) 
Regulations and the Health and Safety at Work Act. 

 

Each  appliance  requires  a  flow  of  fresh  air  for  combustion.  Under  no 
circumstances  should  air  vents  on  the  appliances,  or  air  vents  installed  by  the 
fitter in the room of the appliance to supply combustion air, be altered or omitted 
in any way. 
 
To prevent shocks, all appliances whether gas or electric, must be earthed. 
 

 ANY GAS CONVERSIONS NEEDED TO BE MADE TO THE PRODUCT MUST 
BE CARRIED OUT BY A GAS SAFE REGISTERED ENGINEER 
 

To avoid scratching the highly polished exterior surface of this equipment whilst 
in transit, the protective film on the exterior surfaces has NOT been removed. 
 
It  is  IMPORTANT  that  this  protective  film  is  peeled  off  before  the  equipment  is 
used. 

Содержание GGP6.10

Страница 1: ...TY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS SERVICE INSTRUCTIONS TECHNICAL DETAILS PARTS LIST WARRANTY INFORMATION Customer...

Страница 2: ...ONS and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to the Gas Safety Installation and Use Regulations and the Health and Safety at Work Act Each appliance requir...

Страница 3: ...sion to NAT is possible with conversion kit available Working pressures and heat inputs are listed in the Technical Details 2 Appliances must not be installed on or against any combustible surface Cle...

Страница 4: ...scolds from the cooking medium and hot surfaces of working areas The appliance must be placed in a well ventilated location underneath a suction fan with a suction capacity of at least 1500m3 h The gr...

Страница 5: ...e abort the lighting process for at least 2 minutes to allow gas to disperse 5 Turn knob anti clockwise to obtain main gas The lowest setting has been set at the factory and sealed This must not be ad...

Страница 6: ...by a Gas Safe registered engineer This is essential to maintain safety and prolong life of the appliance PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN FACTORY SET AND SHOULD NOT BE ADJUSTED U...

Страница 7: ...panel To do so loosen the screws that attach the side panels corners This way the whole assembly front panel and corners will come out together The thermocouple and the electrode are attached to the...

Страница 8: ...e burner loosen the nut that connects the 8mm gas pipe to the aluminium part Loosen the nut that connects the thermocouple to the aluminium part and disconnect the piezo ignitor In case there a tap ma...

Страница 9: ...G 3 100 KW 10578 Btu h PROPANE G31 37mb 14 8 W G 3 100 KW 10578 Btu h G25 25mb 10 W G 2 900 KW 9895 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 330 M HR 11 654 FT HR BUTANE G30 0 101 M HR 3 5...

Страница 10: ...G 5 500 KW 18767 Btu h PROPANE G31 37mb 14 8 W G 5 500 KW 18767 Btu h G25 25mb 10 W G 5 000 KW 17061 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 582 M HR 20 553 FT HR BUTANE G30 0 184 M HR 6...

Страница 11: ...G 8 250 KW 28150 Btu h PROPANE G31 37mb 14 8 W G 8 250 KW 28150 Btu h G25 25mb 10 W G 7 500 KW 25591 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 872 M HR 30 794 FT HR BUTANE G30 0 276 M HR 9...

Страница 12: ...G 9 300 KW 31733 Btu h PROPANE G31 37mb 14 8 W G 9 300 KW 31733 Btu h G25 25mb 10 W G 8 700 KW 29686 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 990 M HR 34 962 FT HR BUTANE G30 0 303 M HR 10...

Страница 13: ...012 FRONT PANEL GGP6 8 6 7 0 304 0012 FRONT PANEL GGP6 10 7 7 0 301 0006 REAR PANEL GGP6 4 7 7 0 302 0006 REAR PANEL GGP6 6 7 7 0 303 0006 REAR PANEL GGP6 8 7 7 0 304 0006 REAR PANEL GGP6 10 8 4 0 201...

Страница 14: ...N PILOT SBF 25 4 0 301 0012 PLATE REAR SUPPORT 15x34 5mm GL500 26 4 0 301 0033 GAS TERMOCOUPLE 250MM FASTON 8X1 27 4 0 301 0045 GAS INJECTOR M6x0 75 1 25 GGP6 4 GGP6 10 27 4 0 301 0044 GAS INJECTOR M6...

Страница 15: ...INSTRUCTION REF IN205 ISSUE NO 3 DATE 07 03 12 Page 15 of 18 www parry co uk 15 1 9 8 7 30 1 4 1 1 8 1 7 2 3 25 22 9 1 6 1 3 23 26 24 29 33 28 27 4 5 1 0 1 2 31 32 1 1 21 20 1 5 6...

Страница 16: ...uring the warranty period it is at Parrys discretion to repair or replace the equipment Warranty only applies if the equipment has been used in a professional manor following the manufactures instruct...

Страница 17: ...ss arranged for service call and engineer refused access or customer not there No faults with the machine Setting up of equipment eg dishwasher detergents levelling and setting up of doors on a 6 burn...

Страница 18: ...bove will be forwarded to the parties responsible for placing the call Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled Any is...

Отзывы: