INSTRUCTION REF: IN205
ISSUE NO. 3
DATE 07.03.12
Page 7 of 18
www.parry.co.uk
7
CONVERSION INSTRUCTIONS
Close the gas supply valve.
Disconnect the inlet gas supply.
To replace burner, push it a bit to the back of the equipment and this
loosens the burner from the aluminium part. Replace the old burner with a
new one or replace the injector in case of a change of gas type. To loosen
the injector one must use an adequate nut driver.
Attention: Keep in mind
the rela
tion between the diameter of the injector’s hole and the type of
gas.
To replace the thermocouple and the electrode it is necessary to take out
the front panel. To do so, loosen the screws that attach the side panels’
corners. This way the whole assembly; front panel and corners will come
out together.
The thermocouple and the electrode are attached to the aluminium part,
which is attached to the burner support. In order to take out the aluminium
part, it’s necessary to unscrew the pipe that links the tap to the burner and
the 2 screws that hold the burner frontal support.
The minimum setting is regulated with the burner on turned to the
minimum setting.
Remove the black knob from the gas tap and regulate the frontal screw
which is located below the shaft of the tap.
Adjust the flame to a desired low setting that will have enough heat to
keep the thermocouple hot and keep the flame burning.
Wait for a couple of minutes to make sure that the flame doesn
’t go out.