INSTRUCTION REF: IN205 
ISSUE NO. 3 

DATE 07.03.12 
Page 4 of 18 

 

www.parry.co.uk 

6.  Pressure test point is located underneath the appliance 

– it is located on the 

tap rail. 
 
7.    Low  rate  is  factory  set  for  LPG  gas,  and  only  require  adjustment  when 
converting from LPG to NAT Gases. 
 
8.  Remove all protective film before use. 
 
9.    Ensure  whoever  is  operating  the  appliance  is  fully  conversant  with  its 
operation  and  aware  of  dangers  involved  in  incorrect  operation  and  cleaning, 
especially  the  danger  of  burns  and  scolds  from  the  cooking  medium  and  hot 
surfaces of working areas. 

 
 

 

The  appliance  must  be  placed  in  a  well  ventilated  location, 
underneath a suction fan with a suction capacity of at least 1500m3/h

 

 

 

The  griddle must be secured by placing four M10 sized screws with 
at least 15mm of thread available. 

 

 

In  the  shape  of  a  rectangle,  holes  should  be  drilled  on  the  work 
surface for the location of where the feet will sit 

 

 

 

Screws  will  be  placed  through  the  work  surface  so  the  feet  of  the 
appliance can sit directly on top of the screws so appliance can not 
move 

 

 

Sizes required : GGP6.4   295mm x 332mm 

 

 

Sizes required : GGP6.6   295mm x 532mm 

 

 

Sizes required : GGP6.8   295mm x 732mm 

 

 

Sizes required : GGP6.10  295mm x 932mm  

Содержание GGP6.10

Страница 1: ...TY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS SERVICE INSTRUCTIONS TECHNICAL DETAILS PARTS LIST WARRANTY INFORMATION Customer...

Страница 2: ...ONS and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to the Gas Safety Installation and Use Regulations and the Health and Safety at Work Act Each appliance requir...

Страница 3: ...sion to NAT is possible with conversion kit available Working pressures and heat inputs are listed in the Technical Details 2 Appliances must not be installed on or against any combustible surface Cle...

Страница 4: ...scolds from the cooking medium and hot surfaces of working areas The appliance must be placed in a well ventilated location underneath a suction fan with a suction capacity of at least 1500m3 h The gr...

Страница 5: ...e abort the lighting process for at least 2 minutes to allow gas to disperse 5 Turn knob anti clockwise to obtain main gas The lowest setting has been set at the factory and sealed This must not be ad...

Страница 6: ...by a Gas Safe registered engineer This is essential to maintain safety and prolong life of the appliance PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN FACTORY SET AND SHOULD NOT BE ADJUSTED U...

Страница 7: ...panel To do so loosen the screws that attach the side panels corners This way the whole assembly front panel and corners will come out together The thermocouple and the electrode are attached to the...

Страница 8: ...e burner loosen the nut that connects the 8mm gas pipe to the aluminium part Loosen the nut that connects the thermocouple to the aluminium part and disconnect the piezo ignitor In case there a tap ma...

Страница 9: ...G 3 100 KW 10578 Btu h PROPANE G31 37mb 14 8 W G 3 100 KW 10578 Btu h G25 25mb 10 W G 2 900 KW 9895 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 330 M HR 11 654 FT HR BUTANE G30 0 101 M HR 3 5...

Страница 10: ...G 5 500 KW 18767 Btu h PROPANE G31 37mb 14 8 W G 5 500 KW 18767 Btu h G25 25mb 10 W G 5 000 KW 17061 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 582 M HR 20 553 FT HR BUTANE G30 0 184 M HR 6...

Страница 11: ...G 8 250 KW 28150 Btu h PROPANE G31 37mb 14 8 W G 8 250 KW 28150 Btu h G25 25mb 10 W G 7 500 KW 25591 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 872 M HR 30 794 FT HR BUTANE G30 0 276 M HR 9...

Страница 12: ...G 9 300 KW 31733 Btu h PROPANE G31 37mb 14 8 W G 9 300 KW 31733 Btu h G25 25mb 10 W G 8 700 KW 29686 Btu h GAS RATE M HR FT HR LB HR KG HR NATURAL G20 0 990 M HR 34 962 FT HR BUTANE G30 0 303 M HR 10...

Страница 13: ...012 FRONT PANEL GGP6 8 6 7 0 304 0012 FRONT PANEL GGP6 10 7 7 0 301 0006 REAR PANEL GGP6 4 7 7 0 302 0006 REAR PANEL GGP6 6 7 7 0 303 0006 REAR PANEL GGP6 8 7 7 0 304 0006 REAR PANEL GGP6 10 8 4 0 201...

Страница 14: ...N PILOT SBF 25 4 0 301 0012 PLATE REAR SUPPORT 15x34 5mm GL500 26 4 0 301 0033 GAS TERMOCOUPLE 250MM FASTON 8X1 27 4 0 301 0045 GAS INJECTOR M6x0 75 1 25 GGP6 4 GGP6 10 27 4 0 301 0044 GAS INJECTOR M6...

Страница 15: ...INSTRUCTION REF IN205 ISSUE NO 3 DATE 07 03 12 Page 15 of 18 www parry co uk 15 1 9 8 7 30 1 4 1 1 8 1 7 2 3 25 22 9 1 6 1 3 23 26 24 29 33 28 27 4 5 1 0 1 2 31 32 1 1 21 20 1 5 6...

Страница 16: ...uring the warranty period it is at Parrys discretion to repair or replace the equipment Warranty only applies if the equipment has been used in a professional manor following the manufactures instruct...

Страница 17: ...ss arranged for service call and engineer refused access or customer not there No faults with the machine Setting up of equipment eg dishwasher detergents levelling and setting up of doors on a 6 burn...

Страница 18: ...bove will be forwarded to the parties responsible for placing the call Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled Any is...

Отзывы: