15
GB/IE/NI
ATTENTION!
After welding, the welding clamp and
the welding rod must be set down on the
insulated holder. The fusion slag can only
be removed once the rod has cooled down.
To re-weld the interrupted weld, the fusion
lag must first be removed from the welding
position.
ATTENTION!
A voltage 10 % below the rated input volt-
age of the welding tool may result in:
A drop in the current of the tool.
The arc stopping or becoming unstable.
ATTENTION!
The arc radiation may cause inflamma-
tion of the eye and skin burns.
Spray and fusion slag may cause eye
injuries and burns.
Wear tinted eye goggles or a face
shield.
The face shield must comply with safety
standard EN175.
Only use welding cables included in
delivery (10 mm2).
Note:
Determine which welding method is
more suitable for yourself after welding a test
piece.
Note:
Once it has worn down completely,
the electrode must be replaced.
z
Maintenance and Cleaning
Note:
The welding tool requires regular
maintenance and reconditioning to work
properly and to comply with safety require-
ments. Improper and incorrect operation
may result in malfunctions and damage the
tool.
Start up / Welding / Maintenance and Cleaning
z
Welding
Choose from welding with the tool directed towards the unwelded or the welded part.
The following illustrates how the direction of movement has on the quality of the weld:
Towards the unwelded
part:
Towards the welded
part:
Weld penetration
less
greater
Weld width
larger
smaller
Welding bead
flatter
higher
Weld imperfections
greater
less
Содержание PISG 80 A3
Страница 3: ... schwarz rot 1 2 4 10 9 3 5 6 7 11 8 ...
Страница 4: ...D C3 C4 C1 C2 A B 8 7 7 11 5 ...
Страница 19: ...19 GB IE NI ...
Страница 20: ...20 GB IE NI ...
Страница 37: ......
Страница 38: ......
Страница 39: ......