3. ELECTRICAL INSTALLATION 41
Figure 3-20 shows the input characteristic.
+10V
-10V
Commanded
velocity
Volts
Velocity
(rps)
Dead band
Figure 3-20. Analogue Differential Input Characteristic
Fault Output
The fault output is an independent NPN open-collector output, which is normally ‘low’ active
‘high’. The output ratings are +30V maximum in the OFF condition and 15mA maximum in
the ON condition. Figure 3-21 shows the output circuit.
Fault
Output
Drive
circuit
0V
Figure 3-21. Fault Output Circuit