![Parker ViX250AH Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/parker/vix250ah/vix250ah_user-manual_756266029.webp)
3. ELECTRICAL INSTALLATION 23
Note: keep the motor cable routing within the equipment cabinet at least 300mm away from
I/O cables carrying control signals.
Motor Phase Contactors
We recommend that motor phase contactors are not used within the motor power cables. As
an alternative, make use of the drive’s power stage ‘enable’ control signal.
Ferrite absorber specifications
The absorbers described in these installation instructions use a low-grade ferrite material
that has high losses at radio frequencies. They therefore act like a high impedance in this
waveband. Produced by Parker Chomerics, the recommended component is suitable for use
with cable having an outside diameter up to 10mm. The specification is as follows:
Chomerics part number H8FE-1115-NC (Parker part number 0313.020)
Outside diameter 17.5mm
Inside diameter 10.7mm
Length 28.5mm
Impedance at 25MHz 80 ohm
Impedance at 100MHz 120ohm
Curie temperature 130°C (the device should not be operated near this temperature)