22
VIX AH SERVO DRIVE USER GUIDE
1
W
V
U
GND
MAX
150mm
X1
2
3
4
5
MOTOR
FEEDBACK
LIMITS
TO CONNECTOR X5
Figure 3-8. Position of absorbers & motor wiring details
There must be no break in the 360° coverage that the screen provides around the cable
conductors.
Use of a through connector must retain the 360° coverage, possibly by the use of an
additional metallic casing where it passes through the bulkhead of the enclosure. We
recommend not to bond the cable screen to the cabinet at the point of entry. Its function is
to return high-frequency chopping current back to the drive. This may require mounting the
connector on a sub-panel insulated from the main cabinet, or using a connector having an
insulated internal screen from the connector housing. Within the cabinet itself, all the motor
cables should lie in the same trunking as far as possible. Keep the cables separate from any
low-level control signal cables. This applies particularly where the control cables are
unscreened and run close to the drive.