Section 2.0 - Getting Started 

 

 

Before unpacking/uncrating your new dryer, inspect the carton/crate 
for damage.  Note any damage on the freight bill.  File notice of 
concealed damage if: 
 

(a)

 

there are any dents in the cabinets 

(b)

 

the air and drain pipes are not straight 

(c)

 

there is any sign of oil on the skid or floor 

(d)

 

the refrigerant gauges show NO pressure 

 

File these claims with the carrier immediately! 

 
Otherwise, proceed with unpacking/uncrating the unit. 
 
 
Environmental & Location Considerations 
 

Following these guidelines will help insure that your new dryer will provide safe and 
reliable service. 

 

ƒ

 

Unless supplied for special conditions, air cooled dryers must be located in an 

area with an ambient temperature between 50…95ºF (10…35ºC) and free 
from explosive and corrosive fumes.  Three (3) feet (92cm) of space must 

be allowed between all open grills, walls, or other objects. 

 

ƒ

 

Where ambient temperatures may periodically fall into the 35…50

ºF 

(1.6…10ºC) range, dryers are equipped with a low ambient fan control.

 

 

ƒ

 

Dryers for below freezing (31º, -5ºC) 

ambient temperatures

 are available with an 

optional additional refrigeration condenser bypass valve.

 

 

 

 

           

If the dryer is installed in a confined area, an exhaust system must be      

provided to eliminate recirculation of hot atmospheric air. 

 

 

ƒ

 

High ambient temperatures affect the outlet dew point of the dryer.  For 
every 10º of ambient temperature over 95ºF (35ºC) a decrease of 9% of 

dryer performance is encountered with air cooled dryers.  The unit must not 
operate in an ambient of over 115ºF (46ºC).  If ambient temperature 

conditions are over 95ºF (35º), water cooled dryers are recommended. 

 

Содержание SC80

Страница 1: ...Airtek Division SMART CYCLE COLD TRAP REFRIGERATED AIR DRYERS OPERATORS MANUAL MODELS SC CT80 SC CT3000 SERVICE DEPARTMENT 1 800 451 6023...

Страница 2: ...ection 5 0 SENSORS CONTROLS RELAYS Section 6 0 START UP PROCEDURE Section 6 0 ROUNTINE MAINTENANCE Section 7 0 DIAGNOSTIC CODES Section 8 0 TROUBLE SHOOTING Section 9 0 MAINTENACE SCHEDULE Section 10...

Страница 3: ...ase Heate r WATTS Crankcase Heater Voltage VOLT Number of Fans Fan Motor Horse Power HP Max Amp Draw AMPS copper THHN Wire Size AWG Fuse Size AMP enter n a if not used Nema Starter Size PART Overload...

Страница 4: ...ure between 50 95 F 10 35 C and free from explosive and corrosive fumes Three 3 feet 92cm of space must be allowed between all open grills walls or other objects Where ambient temperatures may periodi...

Страница 5: ...zed when the refrigeration suction gauge reads between 28 to 35 PSI Plumbing the Air Lines The dryers are shipped ready to run All connections are made to the outside of the cabinet Air piping must be...

Страница 6: ...a bypass line and gate valve to permit isolation of the dryer from the air system This is done to provide easy service and or removal of the dryer without interruption of air to the system Fig 2 Model...

Страница 7: ...c box cover from inside unit 2 Locate the wires 3 Locate hole on side of box place and tighten connector run wires through connector 4 Using wire connectors connect Black to Hot wire White to Neutral...

Страница 8: ...Section 4 0 Controls REFRIGERANT DRYER CONTROLLER FEATURES AND OPERATIONS 5 1 4 8 10 2 6 3 7 9...

Страница 9: ...s The set point will change once for each time pressed If the button is pressed and held the set point will change one step per second 5 Set Button Toggles between Actual Display mode and Set Point mo...

Страница 10: ...every 30 minutes independent to the float signal The 30 minute timed intercal setting can be adjusted down to 1 minute or raised up to 60 minutes if desired To adjust the drain Timed Interval setting...

Страница 11: ...ter cooled units 13 High Inlet Temp Display Should not be above 100 F High inlet air temp can cause overloading of dryer If lit check compressed air after cooler and or oil cooler on air compressor 12...

Страница 12: ...lay and LED alarm turns on when the dew point is 15 F above the set point This is also active during any error conditions Compressor Unloader 1 Relay CU1 FU Panel Only Turns on when the dew point is b...

Страница 13: ...panel from unit 4 Some units are shipped with the refrigeration service valve tagged These tagged service valves must not be opened until the dryer is ready to be started and the main power is perman...

Страница 14: ...ow introduce compressed air to the dryer 11 Check the automatic drain for proper operation Drain should open at regular intervals based on the drain control settings Clean Y Strainer after the first 8...

Страница 15: ...ant charge See tag for correct refrigerant charge Unit needs to be pulled into vacuum 500 micron minimum Unit needs to be pulled into vacuum 500 micron minimum The full charge might not be accepted If...

Страница 16: ...tu ua al l d de ew w p po oi in nt t f fa al ll ls s t to o 2 20 0 F F o or r l lo ow we er r U Un nl lo oa ad de er r v va al lv ve e f fa ai il li in ng g t to o o op pe en n R Re ep pl la ac ce e E...

Страница 17: ...e Contact the factory for verification prior to proceeding with this maintenance item MAINTENANCE PROCEDURES Before performing any maintenance on the machine ensure that air pressure is vented from th...

Страница 18: ...bonnets then need to be removed exposing the tube side of the condenser The tube side should be inspected for any debris and cleaned If soft deposits are found they can be cleaned using a pneumatic t...

Страница 19: ...ated by the On Time dial Removing and reapplying power will again actuate the timing cycle Second pushing the test button will actuate the valve for as long as the button is pressed Third once the tim...

Страница 20: ...Section 11 0 MAINTENANCE CHARTS Maintenance Log Date Service Performed Parts Replaced Initials...

Страница 21: ...Section 11 0 MAINTENANCE CHARTS cont Element Replacement Log Part No Date Initials...

Страница 22: ...Section 12 0 ASSOCIATED DRAWINGS...

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ...om FINAL OPERATION CHECK LIST Inlet air temperature is Inlet PSIG is The dew point temperature controller reads between and Air compressor HP or Max SCFM is Is the dryer a minimum of 3 from any struct...

Страница 39: ......

Отзывы: