192-011006N8 PSD1 Installation Guide
192-011006N8 2019-07
09.10.19 09:27
9 (109)
2.5
Order/ type code PSD
1
2
3
4
5
6
7
8
9
10
11
Ordering example
PSD1
M
W
3
433
B
1
1
0
0
000
1
Drive family
PSD1
Parker Servo Drive
2
Device type
S
Stand-Alone 230 VAC
M
Multi axis 400 VAC
3 Mounting type
W
Wall mounting
C
Cold plate*
P
IP20 push through
1)
4
Device type
1
1 performance level
2
2 performance levels
3
3 performance levels
P
Mains modules
5
Device type
PSD1SW1 Stand-Alone
200
2 A
300
5 A
PSD1MW1: 1 performance level
300
5 A
400
8 A
600
15A
800
30 A
PSD1MW2: 2 performance levels
220
2 + 2 A
330
5 + 5 A
440
8 + 8 A
630
15 + 5 A
PSD1MW3: 3 performance levels
222
2 + 2 + 2 A
433
8 + 5 + 5 A
PSD1MWP
010
10 kVA
020
20 kVA
6
Technology
B
Basis
7
Interface
1
EtherCAT
2
Field Bus configurable:
3)
PROFINET, EtherCATIN, Ethernet/IP
8
Feedback
1
Hiperface DSL®
2
Multi-Feedback configurable:
3)
Hiperface DSL®, Resolver, Encoder (1 V
ss
)
2)
, Encoder A/B (TTL)
2)
,
Analog Hall (1 V
ss
)
2)
, EnDat 2.2
1)
,
BISS C
1)
9
Option 1
0
No option
1
Functional safety over EtherCATIN
10 Option 2
0
No option
11 Customized
000
Non customized
1)
In development
2)
in the first expansion stage only forPSD1-S and PSD1MW1...: Multi axes device
with one powerstage
3)
configurable in PSD ServoManager
2.6
Designated use
The device is designed for operation in electric power drive systems (EN 50178).
Motion sequences can be automated with this device. Several motion sequences
can be can combined by interconnecting several of these devices. Mutual
interlocking functions must be incorporated for this purpose.
Please respect the
technical data
(see page 93)!
Exceeding / not respecting its intended use or its limits may cause danger.
•
Motion sequence may not be carried out correctly which can cause personal
injuries or material damages.