Parker Pro Display 10 Instruction Book
50/53
Table 34: ESD, IP, Atmosphere, corrosion endurance, readability
Test Description
Specification
Test level/ Rating
Electrostatic discharge
operation
ISO 10605
•
IV
•
8kV contact and 15kV air.
Electrostatic discharge
handling
ISO 10605
•
IV
•
8kV contact and 15kV air.
Ingress protection IP65
Dust Ingress
IEC 60529
•
Category 1
•
IP6X
Ingress protection IP65
Water Ingress
IEC 60529
•
IPX5
Salt mist
EN 60068-2-52 Test Kb
•
Severity: 2
•
Test time: 72 hours
Chemical brush exposure
ISO 15003
•
Temperature: 25 °C
•
Test humidity: 50 % RH
•
Test time: 100 h
Chemicals:
•
Urea nitrogen saturated
solution
•
Liquid lime 10 %
•
NPK fertilizer (7,5 % N, 7.5
% P, 7.5 % K) saturated
solution
•
Ammonium hydroxide 20
% aqueous solution
•
Diesel fuel 100 %
•
Petrol 100 %
•
Hydraulic oil 100 %
•
Ethylene glycol 50 %
aqueous solution
•
Engine oil 100 %
•
Calcium chloride
Solar radiation
EN 60068-2-5
•
Temperature: +40 °C
•
Exposure time: 10 d
•
UV radiation wavelength:
280 nm...400 nm
Readability
EP 455