13
Bulletin HY22-3220A/US
Instruction Manual
550 Series Hydraulic Power Units
4-WAY VALVE (ALL D03 SIZE)
CODE DESCRIPTION (For use only with Circuit Codes D0 and D1)
NNN
No 4-Way Valve Included
01Y
Closed Center, 120 VAC, Conduit Connectors
01T
Closed Center, 240 VAC, Conduit Connectors
01K
Closed Center, 12 VDC, Conduit Connectors
01J
Closed Center, 24 VDC, Conduit Connectors
02Y
Open Center, 120 VAC, Conduit Connectors
02T
Open Center, 240 VAC, Conduit Connectors
02K
Open Center, 12 VDC, Conduit Connectors
02J
Open Center, 24 VDC, Conduit Connectors
07Y
Float Center, 120 VAC, Conduit Connectors
07T
Float Center, 240 VAC, Conduit Connectors
07K
Float Center, 12 VDC, Conduit Connectors
07J
Float Center, 24 VDC, Conduit Connectors
08Y
Tandem Center, 120 VAC, Conduit Connectors
08T
Tandem Center, 240 VAC, Conduit Connectors
08K
Tandem Center, 12 VDC, Conduit Connectors
08J
Tandem Center, 24 VDC, Conduit Connectors
30Y
Single Solenoid, 120 VAC, Conduit Connector
30T
Single Solenoid, 240 VAC, Conduit Connector
30K
Single Solenoid, 12 VDC, Conduit Connector
30J
Single Solenoid, 24 VDC, Conduit Connector
Y01
Closed Center, 120 VAC, Hirschmann w/out Plugs
T01
Closed Center, 240 VAC, Hirschmann w/out Plugs
K01
Closed Center, 12 VDC, Hirschmann w/out Plugs
J01
Closed Center, 24 VDC, Hirschmann w/out Plugs
Y02
Open Center, 120 VAC, Hirschmann w/out Plugs
T02
Open Center, 240 VAC, Hirschmann w/out Plugs
K02
Open Center, 12 VDC, Hirschmann w/out Plugs
J02
Open Center, 24 VDC, Hirschmann w/out Plugs
Y07
Float Center, 120 VAC, Hirschmann w/out Plugs
T07
Float Center, 240 VAC, Hirschmann w/out Plugs
K07
Float Center, 12 VDC, Hirschmann w/out Plugs
J07
Float Center, 24 VDC, Hirschmann w/out Plugs
Y08
Tandem Center, 120 VAC, Hirschmann w/out Plugs
T08
Tandem Center, 240 VAC, Hirschmann w/out Plugs
K08
Tandem Center, 12 VDC, Hirschmann w/out Plugs
J08
Tandem Center, 24 VDC, Hirschmann w/out Plugs
Y30
Single Solenoid, 120 VAC, Hirschmann w/out Plug
T30
Single Solenoid, 240 VAC, Hirschmann w/out Plug
K30
Single Solenoid, 12 VDC, Hirschmann w/out Plug
J30
Single Solenoid, 24 VDC, Hirschmann w/out Plug
550
MOTOR SELECTION - TEFC
Single Phase = 115/230 VAC, 60 HZ
Three Phase = 230/460 VAC, 60 HZ
CODE
HP
RPM
PHASE
TC
.50
1725
Single
TD
.50
1725
Three
TM
.50
3450
Single
TT
.50
3450
Three
TE
.75
1725
Single
TF
.75
1725
Three
TN
.75
3450
Single
TU
.75
3450
Three
TJ
1.0
1725
Single
TK
1.0
1725
Three
TP
1.0
3450
Single
TW
1.0
3450
Three
TL
1.5
1725
Single
TO
1.5
1725
Three
TQ
1.5
3450
Single
TX
1.5
3450
Three
TV
2.0
1725
Single
TR
2.0
1725
Three
TS
2.0
3450
Single
TY
2.0
3450
Three
PUMP SIZE
CODE DISPLACEMENT
04
.04 CIPR
07
.07 CIPR
10
.10 CIPR
14
.14 CIPR
17
.17 CIPR
20
.20 CIPR
RESERVOIR
CODE VOLUME
05
0.5 Gal. Steel
10
1.0 Gal. Steel
15
1.5 Gal. Steel
50
5.0 Gal. Steel
06
0.5 Gal. Plastic
11
1.0 Gal. Plastic
16
1.5 Gal. Plastic
26
2.5 Gal. Plastic
CIRCUIT
CODE DESCRIPTION
D0
D03 Pad & Extension Fittings
D1
D03 Pad with Dual PO Check Manifold (Manapak)
(for use with D03 Directional Control Valves)
SA
Standard Pressure & Tank Ports
SW
Std P & T Ports with Outlet Port Check Valve
Two Position Two Way Cartridge Valves
Following circuits include outlet port check valve:
S1
12 VDC, Normally Closed, Conduit Connector
S2
24 VDC, Normally Closed, Conduit Connector
S3
120 VAC, Normally Closed, Conduit Connector
S4
240 VAC, Normally Closed, Conduit Connector
S5
12 VDC, Normally Open, Conduit Connector
S6
24 VDC, Normally Open, Conduit Connector
S7
120 VAC, Normally Open, Conduit Connector
S8
240 VAC, Normally Open, Conduit Connector
P1
12 VDC, Normally Closed, DIN Connector
P2
24 VDC, Normally Closed, DIN Connector
P3
120 VAC, Normally Closed, DIN Connector
P4
240 VAC, Normally Closed, DIN Connector
P5
12 VDC, Normally Open, DIN Connector
P6
24 VDC, Normally Open, DIN Connector
P7
120 VAC, Normally Open, DIN Connector
P8
240 VAC, Normally Open, DIN Connector
FLOW CONTROL
(for use with Cartridge Valves)
CODE DESCRIPTION
NN
None (use with D0 and D1 circuits)
HP
None (use with all other circuits)
F1
Pressure Compensated, 2 to 4 LPM (.5 to 1.0 GPM)
F2
Pressure Compensated, 4 to 8 LPM (1.0 to 2.0 GPM)
RV SETTING
In multiples of 100 psi
Examples
04 = 400 psi
12 = 1200 psi
29 = 2900 psi
550 POWER UNIT
- includes relief
valve
Note: 5 gal. steel reservoir
can be mounted vertically
only. All others are vertical
and horizontal ready
(100 psi = 6.8 bar)
NN
None Customer Supplied
“No Motor” note:
A 56C adapter kit is
available enabling the
customer to provide and
mount a standard 56C
with base electric motor.
Standard Product Model Code
Parker Hannifin
HPS Division
New Hope, MN 55428 USA