background image

3

Bulletin HY22-3220A/US

Instruction Manual

550 Series Hydraulic Power Units

Introduction and Description

Introduction

This manual provides descriptive operation and maintenance 

instructions for 550 Series Power Units manufactured by the 

Parker Hannifin Corporation, Oildyne Division. Any additional 

information may be obtained from Parker by referencing the 

unit part number stamped on the product label or by contacting 

your local authorized Parker Distributor. 

Some of the Information in this manual may not apply to all 

power units. Information about custom units may require service 

and application information from other sources. 

Warning 

This Instruction Manual should be read in its entirety and 

understood prior to installing and operating the Oildyne 

550 Series Hydraulic Power Units.

It is imperative that personnel involved in the installation, 

service, and operation of the Oildyne units be familiar with 

how the equipment is to be used. They should be aware of 

the limitations of the system and its component parts, and 

have knowledge of good hydraulic practices in terms of safety, 

installation, and maintenance.

Explanation of Warning Labels

The following labels will be used in this Instruction Manual and 

on all applicable Oildyne products.

Description

The 550 Series Hydraulic Power Unit consists of an AC electric 

motor, fixed displacement gear pump, relief valve and reservoir 

with options for different circuit types incorporating NG6/D03 

valves or 2 position/2 way cartridge valves.  The gear pump is 

driven through a coupling located between the electric motor 

drive shaft and the pump drive shaft.

For dimensional drawings please see pages 4 to 6.

Two basic versions are available, either with SAE-6 (9/16-18) 

ports for the P and T connections, or with JIC-6 male extension 

tube fittings for use with the NG6/D03 version of the adapter.

For hydraulic schematics, please see pages 7 and 8. 

The life expectancy of Parker Oildyne power units is directly tied 

to the frequency of use, the product in which it is incorporated 

and the application.

Shipping weights for the 550 Series Power Units range from 

14.5 kg (36 lbs) to 50 kg (110 lbs).

The 550 Series Power Units are intended to be used in a variety 

of applications, specified by the customer, where pressurized 

hydraulic fluid is needed to move an actuator(s), charge an 

accumulator(s) or supply test equipment.

Pressure Capability (depends on pump/motor combination):
•  Up to 207 bar (3000 psi) maximum

Flow Output (depends on pump/motor combination):
•  At 1725 rpm: .95 – 5.6 lpm (.25 – 1.5 gpm)
•  At 3450 rpm: 1.9 – 11.4 lpm (.5 – 3 gpm) 

Motor Specifications:
•  .37 – 2.2 kW (.5 – 3 HP)
•  56C with base
• TEFC

Voltages (standard motors are 60 Hz):
•  Single phase: 115/208-230 VAC
•  Three phase: 208-230/460 VAC
50 Hz motors are available upon request.

Acceptable Fluids:
•  Standard Automatic Transmission Fluid (ATF)
•  Most mineral based hydraulic fluids 

Viscosity range:  32-64 cSt (150-300 SSU) at 38°C (100°F)  

Please contact Parker Oildyne to discuss any alternate fluids.

Parker Oildyne takes no responsibility if unapproved 

alternative fluids are used.

Temperature Ranges:
Operating: 

-7 to 60°C (+20 to 140°F)

Storage: 

-10 to 60°C (+14 to 140°F)

550 Series Power Units should be installed indoors in a clean 

environment.

550 Series Power Units are designed for a continuous duty. 

However, do not operate the power unit with pump flow going 

over the relief valve for any length of time; this creates excessive 

heat. It is recommended that for any applications requiring a 

maintained pressure, a circuit be selected which incorporates a 

load holding check valve(s). Examples of these circuits would be 

the D1, using the Manapak double pilot operated check valves, 

or a two position/two way cartridge valve with included check 

valve. 

There may be hydraulic liquid under 

pressure. Do not open unit or break pipe 

connections until hydraulic pressure has 

been released.

Be careful; take precautions; examine 

instructions before operation.

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Содержание Oildyne 550 Series

Страница 1: ...Oildyne 550 Series Hydraulic Power Units Bulletin HY22 3220A US Instruction Manual Effective August 01 2011 416181...

Страница 2: ...sible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems Offer of Sale Please contact your...

Страница 3: ...se see pages 7 and 8 The life expectancy of Parker Oildyne power units is directly tied to the frequency of use the product in which it is incorporated and the application Shipping weights for the 550...

Страница 4: ...11 80 88 9 3 50 87 4 3 44 171 5 6 75 135 1 5 32 SINGLE PHASE ONLY FILLER BREATHER 101 6 169 1 4 00 6 50 65 0 2 56 182 1 MAX 7 17 165 1 6 50 76 2 3 00 62 0 2 44 62 0 2 44 4X 8 6 34 SLOT 4 LITER 5 6 LIT...

Страница 5: ...TR THD O RING PORTS P T 304 8 12 00 1 GAL 4 LITER 406 4 16 00 1 1 2 GAL 5 6 LITER 101 3 3 99 24 1 0 95 140 4 5 53 MOTOR HEIGHT 237 2 299 7 9 34 11 80 SINGLE PHASE ONLY FILLER BREATHER RELIEF VALVE RET...

Страница 6: ...10 00 304 8 12 00 25 8 1 02 171 5 6 75 598 8 23 58 311 3 12 26 51 3 2 02 131 8 5 19 63 6 2 51 58 6 2 31 231 6 9 12 66 8 2 63 82 6 3 25 39 9 1 57 93 5 3 68 215 9 8 50 181 7 13 GAUGE PORT LOCATION SAE 6...

Страница 7: ...Instruction Manual 550 Series Hydraulic Power Units Power Unit Schematics Hydraulic Schematics P T P T P T P T SA CIRCUIT SW CIRCUIT S1 S4 P1 P4 CIRCUITS S5 S8 P5 P8 CIRCUITS Parker Hannifin HPS Divis...

Страница 8: ...NSATED FLOW CONTROL F1 OR F2 S5 S8 P5 P8 CIRCUITS WITH PRESSURE COMPENSATED FLOW CONTROL F1 OR F2 D0 CIRCUIT D03 VALVE TO BE SELECTED D1 CIRCUIT INCLUDES MANAPAK DUAL P0 CHECK VALVE D03 VALVE TO BE SE...

Страница 9: ...s Power Units are complete assemblies A small portion is created without the electric motors allowing the customer to purchase and install alternate motors There is a C face kit available Oildyne part...

Страница 10: ...most mineral based hydraulic fluids with viscosities between 32 cSt 150 SSU and 64 cSt 300 SSU at 38 C 100 F For fluids other than these please contact Oildyne Division with the details If users wish...

Страница 11: ...ted emissions should be performed in accordance with the Electromagnetic Compatibility EMC Generic Emissions standards for environments appropriate to the end use product to confirm compliance with th...

Страница 12: ...sed Conduit Connector S3 120 VAC Normally Closed Conduit Connector S4 240 VAC Normally Closed Conduit Connector S5 12 VDC Normally Open Conduit Connector S6 24 VDC Normally Open Conduit Connector S7 1...

Страница 13: ...s T01 Closed Center 240 VAC Hirschmann w out Plugs K01 Closed Center 12 VDC Hirschmann w out Plugs J01 Closed Center 24 VDC Hirschmann w out Plugs Y02 Open Center 120 VAC Hirschmann w out Plugs T02 Op...

Страница 14: ...posite reservoirs it is recommended to remove the filler cap and use a siphon to remove the oil Dispose of or recycle the used fluid according to local regulations Once the fluid is removed an examina...

Страница 15: ...ower Recommendations at Flow Pressure Pump Size Nominal GPM Pressure Bar PSI 1725 3450 34 500 69 1000 103 1500 138 2000 172 2500 207 3000 04 50 HP 50 HP 50 HP 50 HP 50 HP 50 HP 04 50 HP 50 HP 50 HP 75...

Страница 16: ...not return promptly to the neutral position the pump flow will be dumping continuously This builds up heat rapidly If a relief valve is set too low part of the oil will be dumped across the valve wit...

Страница 17: ...lation instructions Will not build pressure Reservoir does not have enough fluid Fill the reservoir per the Installation instructions with an approved fluid Motor rotation is not clockwise from fan en...

Страница 18: ...currently Only one solenoid can be energized at any given time to prevent coil burnout Ensure voltage signals are interlocked to prevent this condition Mechanical damage to leads Replace all damaged w...

Страница 19: ...ted either electronically or by post Description Oildyne 550 Series Power Units Model Number As Applies Sizes All Serial Number All The following standards have either been referred to or complied wit...

Страница 20: ...7272 505 800 parker easteurope parker com LV Latvia Riga Tel 371 6 745 2601 parker latvia parker com MX Mexico Apodaca Tel 52 81 8156 6000 MY Malaysia Shah Alam Tel 60 3 7849 0800 NL The Netherlands...

Отзывы: