9

Bulletin HY22-3220A/US

Instruction Manual

550 Series Hydraulic Power Units

Installation

Suitable applications for the 550 Series Power Units would be 

those whose requirements fall within the operating parameters 

given above.

Some examples of abnormal uses of this unit would include:
•  Use of unit with higher pressure than that for which it was 

rated

•  Use requiring continuous running of the pump flow over the 

pressure relief valve

•  Use with higher or lower voltage than required for optimal 

use

•  Use in a mounting orientation other than that for which it was 

designed

•  Use of fluids not recommended for use 

Parker Hannifin Corporation takes no responsibility for safety 

of any unit if it is not used for the intended purposes detailed in 

this Instruction Manual.

Preparation for Use 

Unpacking and Checking 

All units were carefully packed, in containers or boxes, and may 

or may not be on skids.  In any case, do not remove anything 

from the skid or any packaging until it has been carefully 

checked for damage that may have occurred in transit.  Report 

all damage immediately to the carrier and send a copy to the 

vendor. 

All open ports on the power unit were plugged at the factory to 

prevent the entry of contamination. These plugs must not be 

removed until just before piping connections are made to the 

unit. 

Storage 

If the unit is not going to be installed immediately, it should be 

stored indoors, covered with waterproof sheet, and all open 

ports kept plugged. If long term storage is expected (6 months 

or more) we recommend filling the reservoir completely with 

clean hydraulic fluid to prevent the entry of moisture. 

Removing from packaging

The mass of 550 Series Power Units is unequally distributed 

in the assembly. The electric motors are the ‘heavy ends’ 

of the power units with the standard motors alone weighing 

between 8.3 kg (18.2 lbs) and 22 kg (48.4 lbs).  It is strongly 

recommended that two people carry and move these power 

units. The exception is the 550 Series Power Unit using the 19 

liter (5 gallon) rectangular steel reservoir. These are assembled 

with the electric motor above the reservoir.  550 Series Power 

Units with the 19 liter (5 gallon) rectangular steel reservoir should 

be removed from the skid by wrapping a heavy duty nylon strap 

around the base of the motor mounting feet. This strap should 

be firmly secured to the lift truck forks when unit is lifted. 

Installation 

Locating Power Unit 

The unit should preferably be installed indoors in a clean, dry 

environment with an ambient temperature of 15 to 38°C (60 to 

100°F).  

Parker Oildyne products should not be installed where they are 

at risk of objects falling from overhead or where there is any risk 

of impact with external objects.

Mounting the power unit

The majority of 550 Series Power Units are complete 

assemblies.  A small portion is created without the electric 

motors, allowing the customer to purchase and install alternate 

motors.  There is a ‘C-face’ kit available, Oildyne part number 

775679, which allows a standard ‘56C with base’ motor to be 

mounted to the 550 Series. This kit includes a spacer plate, 

shaft adapter with set screw, threaded studs and nuts – all the 

components needed to mount the motor to the power unit.  See 

the Appendix on page 18 for installation instructions using this 

C face kit.

550 Series Power Units are assembled for mounting horizontally 

(ports or D03 valve facing UP) or vertically (motor above the 

reservoir), except for power units using the 19 liter (5 gallon) 

reservoir, which are designed only for vertical installation (motor 

above the reservoir).

For port locations see pages 4 - 6.

Mount the power unit securely through the provided slots in 

the motor foot.  See page 4 for the motor foot details.  Power 

units with the 19 liter (5 gallon) reservoir will use the reservoir 

base flanges to mount to the customer determined location.  

See page 6 for reservoir mounting flange details. Mounting 

bolt torque values will be determined by the type of fastener 

selected by the customer.

 It is strongly recommended that 

the surface to which the power unit is mounted is bonded 

to earth to provide proper grounding in the event of a 

lightning strike.

Electrical Service Connections 

Connect the motor to the power source following good 

practices as outlined in the national electric codes and any local 

codes which may apply.  Verify that the available voltage is the 

same as the voltage identified on the label. Most AC motors 

have dual voltage ratings, so verify that the leads in the conduit 

box have been connected together as defined on the motor 

nameplate to match the facility power source available. Ensure 

the wiring connections will provide clockwise motor rotation, 

when looking at the fan end.

Standard NEMA motor connections are shown here:

Single phase - 115/208/230 VAC

1 3 5  2 4 8

LINE LINE

1 Ø, Low Voltage

TAPE LINE

2 3 5 4  8

1

LINE

1 Ø, High Voltage

 

 

Three phase - 230/460 VAC

If the 3 phase connection shown results in a counter clockwise 

rotation (from the fan end), interchange any two of the three L1, 

L2, L3 connections to reverse the motor rotation.

 

3 Ø, Low Voltage

TAPE

L 3

4 5 6

3  9

L 1

1  7 2  8

L 2

3 Ø, High Voltage

1

L 1

2

L 2

3

L 3

4  7

TAPE TAPE

5  8

TAPE

6  9

 

Customer supplied controls will include motor starters and valve 

operators (for NG6/D03 and solenoid cartridge valves).

Supply and Return Connections 

550 Series Power Units incorporating an NG6/D03 valve 

surface, regardless of the valve being supplied by Oildyne or 

not, will include two JIC-6 (9/16-18) extensions fittings onto 

which the A and B actuator control connections can be made.  

Power units incorporating the P and T ports have two SAE-6 

(9/16-18) female o-ring type ports to accept customer fittings.  

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Содержание Oildyne 550 Series

Страница 1: ...Oildyne 550 Series Hydraulic Power Units Bulletin HY22 3220A US Instruction Manual Effective August 01 2011 416181...

Страница 2: ...sible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems Offer of Sale Please contact your...

Страница 3: ...se see pages 7 and 8 The life expectancy of Parker Oildyne power units is directly tied to the frequency of use the product in which it is incorporated and the application Shipping weights for the 550...

Страница 4: ...11 80 88 9 3 50 87 4 3 44 171 5 6 75 135 1 5 32 SINGLE PHASE ONLY FILLER BREATHER 101 6 169 1 4 00 6 50 65 0 2 56 182 1 MAX 7 17 165 1 6 50 76 2 3 00 62 0 2 44 62 0 2 44 4X 8 6 34 SLOT 4 LITER 5 6 LIT...

Страница 5: ...TR THD O RING PORTS P T 304 8 12 00 1 GAL 4 LITER 406 4 16 00 1 1 2 GAL 5 6 LITER 101 3 3 99 24 1 0 95 140 4 5 53 MOTOR HEIGHT 237 2 299 7 9 34 11 80 SINGLE PHASE ONLY FILLER BREATHER RELIEF VALVE RET...

Страница 6: ...10 00 304 8 12 00 25 8 1 02 171 5 6 75 598 8 23 58 311 3 12 26 51 3 2 02 131 8 5 19 63 6 2 51 58 6 2 31 231 6 9 12 66 8 2 63 82 6 3 25 39 9 1 57 93 5 3 68 215 9 8 50 181 7 13 GAUGE PORT LOCATION SAE 6...

Страница 7: ...Instruction Manual 550 Series Hydraulic Power Units Power Unit Schematics Hydraulic Schematics P T P T P T P T SA CIRCUIT SW CIRCUIT S1 S4 P1 P4 CIRCUITS S5 S8 P5 P8 CIRCUITS Parker Hannifin HPS Divis...

Страница 8: ...NSATED FLOW CONTROL F1 OR F2 S5 S8 P5 P8 CIRCUITS WITH PRESSURE COMPENSATED FLOW CONTROL F1 OR F2 D0 CIRCUIT D03 VALVE TO BE SELECTED D1 CIRCUIT INCLUDES MANAPAK DUAL P0 CHECK VALVE D03 VALVE TO BE SE...

Страница 9: ...s Power Units are complete assemblies A small portion is created without the electric motors allowing the customer to purchase and install alternate motors There is a C face kit available Oildyne part...

Страница 10: ...most mineral based hydraulic fluids with viscosities between 32 cSt 150 SSU and 64 cSt 300 SSU at 38 C 100 F For fluids other than these please contact Oildyne Division with the details If users wish...

Страница 11: ...ted emissions should be performed in accordance with the Electromagnetic Compatibility EMC Generic Emissions standards for environments appropriate to the end use product to confirm compliance with th...

Страница 12: ...sed Conduit Connector S3 120 VAC Normally Closed Conduit Connector S4 240 VAC Normally Closed Conduit Connector S5 12 VDC Normally Open Conduit Connector S6 24 VDC Normally Open Conduit Connector S7 1...

Страница 13: ...s T01 Closed Center 240 VAC Hirschmann w out Plugs K01 Closed Center 12 VDC Hirschmann w out Plugs J01 Closed Center 24 VDC Hirschmann w out Plugs Y02 Open Center 120 VAC Hirschmann w out Plugs T02 Op...

Страница 14: ...posite reservoirs it is recommended to remove the filler cap and use a siphon to remove the oil Dispose of or recycle the used fluid according to local regulations Once the fluid is removed an examina...

Страница 15: ...ower Recommendations at Flow Pressure Pump Size Nominal GPM Pressure Bar PSI 1725 3450 34 500 69 1000 103 1500 138 2000 172 2500 207 3000 04 50 HP 50 HP 50 HP 50 HP 50 HP 50 HP 04 50 HP 50 HP 50 HP 75...

Страница 16: ...not return promptly to the neutral position the pump flow will be dumping continuously This builds up heat rapidly If a relief valve is set too low part of the oil will be dumped across the valve wit...

Страница 17: ...lation instructions Will not build pressure Reservoir does not have enough fluid Fill the reservoir per the Installation instructions with an approved fluid Motor rotation is not clockwise from fan en...

Страница 18: ...currently Only one solenoid can be energized at any given time to prevent coil burnout Ensure voltage signals are interlocked to prevent this condition Mechanical damage to leads Replace all damaged w...

Страница 19: ...ted either electronically or by post Description Oildyne 550 Series Power Units Model Number As Applies Sizes All Serial Number All The following standards have either been referred to or complied wit...

Страница 20: ...7272 505 800 parker easteurope parker com LV Latvia Riga Tel 371 6 745 2601 parker latvia parker com MX Mexico Apodaca Tel 52 81 8156 6000 MY Malaysia Shah Alam Tel 60 3 7849 0800 NL The Netherlands...

Отзывы: