background image

AE – UAE, 

Dubai 

Tel:  +971 4 8127100 
[email protected]

AR – Argentina, 

Buenos Aires 

Tel:  +54 3327 44 4129

AT – Austria, 

Wiener Neustadt 

Tel:  +43 (0)2622 23501-0 
[email protected]

AT – Eastern Europe,  

Wiener Neustadt 
Tel: +43 (0)2622 23501 900 
[email protected]

AU – Australia, 

Castle Hill 

Tel: +61 (0)2-9634 7777

AZ – Azerbaijan, 

Baku 

Tel: +994 50 2233 458 
[email protected]

BE/LU – Belgium, 

Nivelles 

Tel: +32 (0)67 280 900 
[email protected]

BR – Brazil, 

Cachoeirinha RS 

Tel: +55 51 3470 9144

BY – Belarus, 

Minsk 

Tel: +375 17 209 9399 
[email protected]

CA – Canada, 

Milton, Ontario 

Tel: +1 905 693 3000

CH – Switzerland, 

Etoy 

Tel: +41 (0) 21 821 02 30  
[email protected]

CL – Chile, 

Santiago

 

Tel: +56 2 623 1216

CN – China, 

Shanghai 

Tel: +86 21 2899 5000

CZ – Czech Republic, 

Klecany 

Tel: +420 284 083 111 
[email protected]

DE – Germany, 

Kaarst 

Tel: +49 (0)2131 4016 0 
[email protected]

DK – Denmark, 

Ballerup 

Tel: +45 43 56 04 00 
[email protected]

ES – Spain, 

Madrid 

Tel: +34 902 330 001 
[email protected]

FI – Finland, 

Vantaa 

Tel: +358 (0)20 753 2500 
[email protected]

FR – France, 

Contamine s/Arve 

Tel: +33 (0)4 50 25 80 25 
[email protected]

GR – Greece, 

Athens 

Tel: +30 210 933 6450 
[email protected]

HK – Hong Kong 

Tel: +852 2428 8008

HU – Hungary, 

Budapest 

Tel: +36 1 220 4155 
[email protected]

IE – Ireland, 

Dublin 

Tel: +353 (0)1 466 6370 
[email protected]

IN – India, 

Mumbai 

Tel: +91 22 6513 7081-85

IT – Italy, 

Corsico (MI) 

Tel: +39 02 45 19 21 
[email protected]

JP – Japan, 

Fujisawa 

Tel: +(81) 4 6635 3050

KR – South Korea, 

Seoul 

Tel: +82 2 559 0400

KZ – Kazakhstan,

 Almaty 

Tel: +7 7272 505 800 
[email protected]

LV – Latvia, 

Riga 

Tel: +371 6 745 2601 
[email protected]

MX – Mexico, 

Apodaca 

Tel: +52 81 8156 6000

MY – Malaysia, 

Shah Alam 

Tel: +60 3 7849 0800

NL – The Netherlands,  

Oldenzaal 
Tel: +31 (0)541 585 000 
[email protected]

NO – Norway, 

Asker 

Tel: +47 66 75 34 00 
[email protected]

NZ – New Zealand, 

Mt Wellington 

Tel: +64 9 574 1744

PL – Poland, 

Warsaw 

Tel: +48 (0)22 573 24 00 
[email protected]

PT – Portugal, 

Leca da Palmeira 

Tel: +351 22 999 7360 
[email protected]

Parker Worldwide

Your local authorized Parker distributor

RO – Romania, 

Bucharest 

Tel: +40 21 252 1382 
[email protected]

RU – Russia, 

Moscow 

Tel: +7 495 645-2156 
[email protected]

SE – Sweden, 

Spånga 

Tel: +46 (0)8 59 79 50 00 
[email protected]

SG – Singapore 

Tel: +65 6887 6300

SK – Slovakia, 

Banská Bystrica

 

Tel: +421 484 162 252 
[email protected]

SL – Slovenia, 

Novo Mesto 

Tel: +386 7 337 6650 
[email protected]

TH – Thailand, 

Bangkok 

Tel: +662 717 8140

TR – Turkey, 

Istanbul 

Tel: +90 216 4997081 
[email protected]

TW – Taiwan, 

Taipei 

Tel: +886 2 2298 8987

UA – Ukraine, 

Kiev 

Tel +380 44 494 2731 
[email protected]

UK – United Kingdom,  

Warwick 
Tel: +44 (0)1926 317 878 
[email protected]

US – USA, 

Cleveland  

(industrial) 
Tel: +1 216 896 3000

US – USA, 

Lincolnshire  

(mobile) 
Tel: +1 847 821 1500

VE – Venezuela, 

Caracas 

Tel: +58 212 238 5422

ZA – South Africa, 

Kempton Park 
Tel: +27 (0)11 961 0700 
[email protected]

US Product Information Centre

Free phone: 1-800-272-7537

European Product Information 
Centre

Free phone: 00 800 27 27 5374
www.parker.com

Bulletin HY22-3210A/US

.25M, 11/11 BG 

© 2011 Parker Hannifin Corporation. All rights reserved.

Parker Hannifin Corporation

Hydraulic Pump and Power Systems Division 
Oildyne Business Unit
5520 Highway 169 North
New Hope, MN 55428 USA
Ph: 937-644-3915 
Fax: 937-642-3738
www.parker.com/hps

Содержание Oildyne 108 Series

Страница 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Страница 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Страница 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Страница 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Страница 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Страница 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Страница 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Страница 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Страница 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Страница 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Страница 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Страница 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Страница 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Страница 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Страница 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Страница 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Страница 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Страница 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Страница 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Страница 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Страница 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Страница 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Страница 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Страница 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Страница 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...

Страница 26: ...26 Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Notes...