background image

27

Instruction Manual

Oildyne 108/118 and 165/175 Series  
Hydraulic Power Units

Bulletin HY22-3210A/US

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

EC Declaration of Incorporation.

Manufacturer’s Name:

  

Parker Hannifin Corporation

Manufacturer’s Address:

 

Oildyne Division

 

5520 Highway 169 North

 

New Hope, MN 55428 USA

Declare that the partially complete machinery described below conforms to applicable health and safety requirements of 

Part 1 of Annex 1 of Machinery Directive 2006/42/EC taking full account of requirements for pressure equipment. This 

partly completed machinery must not be put into service until the machinery into which it is to be incorporated has been 

declared in conformity with the provisions of the Machinery Directive. Confidential technical documentation has been 

compiled as described in Part B of Annex VII of Machinery Directive 2006/42/EC and is available to European national 

authorities on written request. If a request is received documentation will be transmitted either electronically or by post.
Description:

 

Oildyne 108/118 & 165/175 Series Power Units

Model Number:

 

As Applies

Sizes:

   

All

Serial Number:

   

All

The following standards have either been referred to or complied with in part or in full as relevant: 
ENISO 12100 – 2  

Machinery Safety  

-  

Basic concepts, general principles for design  

 

 

 

– Part 2: Technical principles and specifications.

EN13849 

Machinery Safety  

-  

Safety Related Parts of Control Systems – Part 1: General 

 

 

 

Principles for Design.

EN 982:1996 

Machinery Safety 

Safety requirements for fluid power systems and their 

 

 

 

components – Hydraulics.

Full Name of responsible person

 

Van Mancuso 

Place of signing:

 

Parker Hannifin Corporation 

Oildyne Division 

Position

 

General Manager, Oildyne Division   

5520 Highway 169 North 

 

 

New Hope, MN  55428  USA 

Signature

    

Date

      

March 17, 2011

Full Name of Authorized European Representative

 

Stephen Fryer

Place of signing:

 

Parker Hannifin Ltd. 

Cylinder Division Europe 

Position

    

General Manager, Cylinder Division Europe 

6 Greycaine Road,  

Watford, Hertfordshire. WD24 7QA, UK 

 

Signature

     

Date

     

 March 17, 2011

Declaration of Incorporation

Содержание Oildyne 108 Series

Страница 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Страница 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Страница 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Страница 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Страница 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Страница 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Страница 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Страница 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Страница 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Страница 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Страница 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Страница 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Страница 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Страница 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Страница 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Страница 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Страница 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Страница 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Страница 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Страница 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Страница 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Страница 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Страница 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Страница 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Страница 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...

Страница 26: ...26 Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Notes...