19
108/118 Series: AC Motors - HA/HD
Performance Data
Instruction Manual
Oildyne 108/118 and 165/175 Series
Hydraulic Power Units
Bulletin HY22-3210A/US
Parker Hannifin
HPS Division
New Hope, MN 55428 USA
207
(3000)
172
(2500)
0
1
2
3
4
5
Curr
ent - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
34
(500)
138
(2000)
103
(1500)
69
(1000)
Output Flow
- lpm (cipm)
.100 Pump
with HA / HD Motor
0
.16
.33
.49
.66
.82
(40)
(30)
(20)
(10)
(50)
207
(3000)
172
(2500)
0
2
4
6
8
10
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
34
(500)
138
(2000)
103
(1500)
69
(1000)
Output Flow -
lpm (cipm)
.190 Pump
with HA / HD Motor
0
.33
.66
.98
1.3
1.6
(80)
(60)
(40)
(20)
(100)
207
(3000)
172
(2500)
0
2
4
6
8
10
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
34
(500)
138
(2000)
103
(1500)
69
(1000)
Output Flow -
lpm (cipm)
.250 Pump
with HA / HD Motor
0
.33
.66
.98
1.3
1.6
(80)
(60)
(40)
(20)
(100)
21
41
62
83
103
124
(300)
(1800)
(1500)
(1200)
(900)
(600)
1
2
3
4
5
6
Current - Amps
Current
@ 115 VAC
Flow
Current
@ 230 VAC
Pressure - bar (psi)
0
Output Flow -
lpm (cipm)
.327 Pump
with HA / HD Motor
0
.41
.82
1.3
1.6
2.0
(100)
(75)
(50)
(25)
(125)
Performance Data
NOTE: S2 = 5
Maximum recommended ON time for the HA/HD motors is 5 minutes, afterwhich the