Standard Product Model Codes

MOTOR CODE – 108/118
AE    12 VDC Perm. Mag.
AM   12 VDC Ser. Wnd. 
BE    24 VDC Perm. Mag.
BI     24 VDC Ser. Wnd. 
HA   115 VAC, 1 phase
HD   230 VAC, 1 phase
IA     36 VDC Perm. Mag.

MOTOR CODE – 165/175
AY    12 VDC Perm. Mag. 1 HP
BY    

 VDC Perm. Mag. 1 HP

PRODUCT TYPE

108   108 Power Unit
118   118 Power Unit
165   165 Power Unit
175   175 Power Unit

PUMP TYPE

S

Standard

C

Cold Temp

PUMP SIZE 108/118

PUMP SIZE 165/175

RESERVOIRS

H

½ gal. (2 liters) Steel

I

1 gal. (3.8 liters) Steel

J

1.5 gal. (5.6 liters) Steel

P

¼ gal. (1 liter) Plastic

Q

½ gal. (2 liters) Plastic

R

1 gal. (3.8 liters) Plastic

S

¾ gal. (2.8 liters) Plastic

NOTE: C and D reservoirs are 
available as Vertical Mount ONLY

CIRCUIT TYPE

NN

Single direction

WW Single dir. with check
RR

Reversible

LL

Reversible locking

RB

Reversible with Back Press.

LB

Rev. lock. with Back Press.

Each Solenoid Valve option below includes 

the WW circuit: Use 118 or 175 when coding solenoid valve circuit
Coils use conduit connections

S1

12 VDC, Normally Closed

S2

24 VDC, Normally Closed

S3

120 VAC, Normally Closed (108/118 only)

S4

240 VAC, Normally Closed (108/118 only)

S5

12 VDC, Normally Open

S6

24 VDC, Normally Open

S7

120 VAC, Normally Open (108/118 only)

S8

240 VAC, Normally Open (108/118 only)

PORTS

1

7/16-20 (SAE -4) (108 & 165 only)

2

7/16-24 (Inv. Flare) (108 only)

3

1/8 in Pipe (NPSF) (108 only)

4

1/8 in Pipe (BSPP) (108 & 165 only)

MOUNTING

V

Vertical (motor up)

H

Horizontal

UP RV SETTING
(Left Hand Port)
In multiples of 100 psi
Examples
04 = 400 psi
12 = 1200 psi
29 = 2900 psi

DN RV SETTING
(Right Hand Port)
If Single Direction circuit 
use 00
In multiples of 100 psi
Examples
04 = 400 psi
12 = 1200 psi
29 = 2900 psi

24

10  .16 cc/rev (.010 in

3

/rev)

19  .31 cc/rev (.019 in

3

/rev)

25  .41 cc/rev (.025 in

3

/rev)

32  .52 cc/rev (.032 in

3

/rev)

32 

.52 cc/rev (.032 in

3

/rev)

50 

.82 cc/rev (.050 in

3

/rev)

65  1.06 cc/rev (.065 in

3

/rev)

13 in

3

 (213 cc) usable (108/118 only)

23 in

3

 (377 cc) usable (108/118 only)

26 in

3

 (426 cc) usable

Alternate orientation C

82 in

3

 (1340 cc) usable (108/118 only)

46 in

3

 (754 cc) usable

Standard Product Model Codes

RELIEF VALVE TOLERANCES

Pressure Range - Bar

(PSI)

Tolerance - Bar

(PSI)

14 – 34.4 bar

(200 – 499 psi)

+/- 5.2 bar

(+/- 75 psi)

35.5 – 68.9 bar

(500 – 999 psi)

+/- 6.9 bar

(+/- 100 psi)

70 – 137.9 bar

(1000 – 1999 psi)

+/- 10.3 bar

(+/- 150 psi)

138+ bar

(2000+ psi)

+/- 13.8 bar

(+/- 200 psi)

Содержание Oildyne 108 Series

Страница 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Страница 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Страница 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Страница 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Страница 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Страница 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Страница 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Страница 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Страница 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Страница 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Страница 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Страница 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Страница 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Страница 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Страница 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Страница 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Страница 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Страница 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Страница 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Страница 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Страница 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Страница 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Страница 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Страница 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Страница 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...

Страница 26: ...26 Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Notes...

Страница 27: ...t If a request is received documentation will be transmitted either electronically or by post Description Oildyne 108 118 165 175 Series Power Units Model Number As Applies Sizes All Serial Number All...

Страница 28: ...easteurope parker com LV Latvia Riga Tel 371 6 745 2601 parker latvia parker com MX Mexico Apodaca Tel 52 81 8156 6000 MY Malaysia Shah Alam Tel 60 3 7849 0800 NL The Netherlands Oldenzaal Tel 31 0 54...

Отзывы: