Instruction Manual

Oildyne 108/118 and 165/175 Series  
Hydraulic Power Units

Bulletin HY22-3210A/US

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Installation

Suggested reversing electrical schematics

108/118 Series HA Motors (115 VAC)

 

RELAY 

BLUE 

WHITE

 

BLACK 

RED 

YELLOW 

ORANGE 

GREEN/YELLOW 

7 AMP FUSE 

L-1 

L-2 

CR-1 

CR-1 

CR-1 

CR-2 

CR-2 

CR-2 

CR-1 

CR-2 

L-2 

L-1 

SPDT, Center Off 

Toggle Switch 

CONTROL CIRCUIT 

161-193 mfd, 125V 

CAPACITOR 

108/118 Series HD Motors (230 VAC)

 

L-1 

L-2 

RELAY 

WHITE

 

BLACK 

RED 

GREEN/YELLOW 

4 AMP FUSE 

CR-1 

CR-1 

CR-1 

CR-2 

CR-2 

CR-2 

CR-1 

CR-2 

L-2 

L-1 

SPDT, Center Off 

Toggle Switch 

CONTROL CIRCUIT 

161-193 mfd, 230V 

CAPACITOR 

BLUE 

ORANGE 

YELLOW 

Suggested reversing electrical schematics

108/118 AE/BE/IA and 165/175 AY/BY Motors

 
 
 
 
 
 
 

 

 

SPDT, spring- to-

Center OFF Toggle 

Switch 

CR-1 

MOTOR 

 

Ground 

Toggle Switch 

CR-2 

CR-3 

CR-4 

Term. 2 

Blue or 

Black 

CR-3 

Term. 1 

Green or  

Orange 

CR-2 

CR-1 

CR-4 

 

+ 12 VDC (AE/AY) 
+ 24 VDC (BE/BY) 
+ 36 VDC (IA) 
 

L.H. PORT FLOW

R.H. PORT FLOW

Supply and Return Connections 

108 Series ports: 
•  7/16-20 SAE-4 o-ring type (model code -1)
•  7/16-24 inverted flare (model code -2)
•  1/8 in NPSF (model code -3)
•  1/8 in BSPP (model code -4)

165 Series ports: 
•  7/16-20 SAE-4 o-ring type (model code -1)
•  1/8 in BSPP (model code -4)

Fluid connectors and conductors installed by the customer 

should be selected based on an acceptable safety margin for 

the maximum pressure required in the application.  108/118 

Series Power Unit are capable of up to 207 bar (3000 psi); 

165/175 Series Power Units are capable of up to 241 bar (3500 

psi).  SAE-4 ports are recommended when selecting a power 

unit due to the integrity of the o-ring seal. 1/8 in NPSF ports will 

use standard 1/8 in NPT tapered fittings. 

Use great caution 

when installing these tapered fittings as the aluminum 

adapter casting will crack if the fittings are overtightened. 

 

Use of a thread sealant, whether a PTFE tape or paste, is 

permitted, however, ensure neither the excess tape nor paste is 

allowed to enter the fluid passageways as these contaminants 

could cause problems.

The 118/175 Series versions will not have connectors or 

conductors installed directly, but, instead, will have a customer-

supplied manifold bolted to the flat port surface. Fluid 

connectors and conductors will be installed into the customer-

supplied manifold.

Line sizes should be determined based on oil flow, operating 

pressure and allowable pressure drop between the power unit 

and actuator. 

Warning 

Check to insure that the proper rated hose or pipe is used on 

pressure lines. 

One of the key ingredients for good service and long life from 

a hydraulic system is cleanliness. Because most most dirt 

infiltrates a hydraulic system during installation, we recommend 

the following:

a) All open ports on the power unit, cylinders, etc. must remain 

plugged with tape or plastic plugs until just before the hydraulic 

connections are made.

b) All interconnecting tubing, pipe, or hose should be clean, and 

free of rust, scale and dirt. The ends of all connectors should be 

plugged until just before they are to be installed in the system.

c)  All openings in the reservoir such as the  filler/breather or 

access end covers holes must remain closd during installation.

Hydraulic Fluids

Follow all vendor-supplied instructions for safe handling, use 

and disposal of the fluid selected for operation in this power 

unit.

It is strongly recommended that the customer have available the 

MSDS for the fluid chosen for use in the 108/118 and 165/175 

Series Power Units. Follow all instructions should the fluid spill 

or come in contact with an operator.

It is critical that the reservoir be filled with an approved fluid 

prior to startup of the power unit.  Any system failures due to 

improper fluids being used or operating without the reservoir 

being full of an approved fluid will result in voiding the warranty.

The reservoir must be filled with clean fluid through the filler 

Содержание Oildyne 108 Series

Страница 1: ...Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Instruction Manual Effective June 01 2011 416180...

Страница 2: ...the application follow applicable industry standards and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiari...

Страница 3: ...17 Motor Amperage draw 1 Name address of manufacturer 2 WARNING see page 4 3 WARNING see page 4 4 CE Mark if applicable 5 Year of product manufacture if CE marked 6 Product type 108 118 7 Part number...

Страница 4: ...on of the porting surfaces Refer to ordering shipping paperwork to determine the exact model code of your power unit That model code can be used to evaluate the performance data in this manual See pag...

Страница 5: ...06 1 27 0 8 05 03 75 4 0 8 2 97 03 12 VDC MOTOR Motor Dimensions 1 3 050 A B C AE BE 75 4 126 2 241 3 2 97 4 97 9 50 AM BI 95 8 151 4 266 4 3 77 5 96 10 49 IA 75 4 128 8 244 1 2 97 5 07 9 61 HA HD 100...

Страница 6: ...6 29 4 5 69 144 5 4 44 112 8 4 00 101 6 6 46 164 1 1 21 30 7 5 00 127 3 15 80 5 72 145 3 12 67 321 8 1 15 29 2 1 15 29 2 4 50 114 3 4 50 114 3 1 15 29 2 1 15 29 2 12 67 321 8 4 33 110 1 16 29 4 1 16 2...

Страница 7: ...AL 4 LITER 1 5 GAL 5 6 LITER 7 27 184 6 12 27 311 6 16 27 413 2 5 88 149 2 5 60 142 3 6 88 174 6 THIRD ANGLE PROJECTION P Q S R 1 QUART 1 LITER 1 2 GALLON 2 LITER 3 QUART 3 LITER 1 GALLON 4 LITER 4 43...

Страница 8: ...HY22 3210A US Parker Hannifin HPS Division New Hope MN 55428 USA RV UP DN TRV RV UP DN TRV RV N C UP TRV RV N O UP Power Unit Schematics 108 118 and 165 175 Series NN Circuit 108 118 and 165 175 Serie...

Страница 9: ...e LPRV HPRV UP DN Back Pressure Valve LPRV HPRV TRV TRV Power Unit Schematics 108 118 and 165 175 Series RR Circuit Reversible 108 118 and 165 175 Series RB Circuit Reversible with Back Pressure 108 1...

Страница 10: ...ld take 90 to 120 minutes depending on the ambient conditions The 165 175 Series PM motors are not intended for continuous operation For Motor Duty Cycle Characteristics see pages 17 20 The 108 118 Se...

Страница 11: ...the 108 118 and 165 175 Series Power Units However the HA and HD motors both AC are shipped with a start relay and a start capacitor assembly specific to the motor voltage being used These two compon...

Страница 12: ...VDC Terminal 2 Ground 165 175 Series BY Motor 1 For Single Direction only and Reversible with UP port pressure Terminal 1 Ground Terminal 2 24 VDC 2 Reversible with DN port pressure Terminal 1 24 VDC...

Страница 13: ...thread sealant whether a PTFE tape or paste is permitted however ensure neither the excess tape nor paste is allowed to enter the fluid passageways as these contaminants could cause problems The 118 1...

Страница 14: ...Series Power Units using the A and B reservoirs in a vertical configuration The dipstick head requires a flat blade screwdriver with a blade width of between 9 13 mm 35 to 5 in After filling with the...

Страница 15: ...tuator to return to the power unit reservoir Note the oil from the actuator will only exit the actuator if an external force or spring is moving the actuator back to its home position If a normally cl...

Страница 16: ...he load is mechanically held in place put a rag around the UP or DN port fitting and loosen the port connection The rag should absorb oil leakage as any locked pressure is relieved Repeat this process...

Страница 17: ...3210A US Parker Hannifin HPS Division New Hope MN 55428 USA Performance Data 327 Pump with AE BE Motor 0 10 20 30 40 50 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2...

Страница 18: ...241 3500 207 3000 172 2500 0 12 24 36 48 60 Current Amps Current 12 VDC Flow Current 24 VDC Pressure bar psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 100 Pump with AM BI Motor 0 33 66 9...

Страница 19: ...psi 0 34 500 138 2000 103 1500 69 1000 Output Flow lpm cipm 190 Pump with HA HD Motor 0 33 66 98 1 3 1 6 80 60 40 20 100 207 3000 172 2500 0 2 4 6 8 10 Current Amps Current 115 VAC Flow Current 230 VA...

Страница 20: ...off time to allow the motor to cool to ambient temperature S2 12 V S2 24 V S2 S3 24 V Instruction Manual Oildyne 108 118 and 165 175 Series Hydraulic Power Units Bulletin HY22 3210A US Parker Hannifin...

Страница 21: ...nnections S1 12 VDC Normally Closed S2 24 VDC Normally Closed S3 120 VAC Normally Closed 108 118 only S4 240 VAC Normally Closed 108 118 only S5 12 VDC Normally Open S6 24 VDC Normally Open S7 120 VAC...

Страница 22: ...ers will help remove the strainer In horizontally mounted configurations the suction strainer is usually installed over an o ring of the suction elbow Again using a pair of pliers clamped on the strai...

Страница 23: ...hours and verified that the class of oil meets the requirements of the pump being used Change the oil every 1000 to 2000 hours depending on the application and operation environment Hydraulic Fluids...

Страница 24: ...a load Ensure test valves are open unrestricted Amp draw is too high Incorrect motor input voltage Verify correct voltage is used Motor stalls out or quits Fuse blown Ensure correct fuse size is used...

Страница 25: ...eservoir too small Install correctly sized reservoir Oil level in tank too low Add oil to reservoir Leaks at port Fitting is cross threaded If not damaged reinstall fitting Fitting isn t tight Tighten...