Parker Hannifin Manufacturing Srl
user’s manual MDC
43
OBJECT DESCRIPTION
INDEX
605Bh
Name
Shutdown option code
Object Code
VAR
Data Type
INTEGER16
Category
Optional
ENTRY DESCRIPTION
Access
rw
PDO Mapping No
Value Range
INTEGER16
Default Value 0
DATA DESCRIPTION
Value
Description
-32768 ... –1 manufacturer specific
0
Disable drive function
1
Slow down with slow down ramp; disable of the drive function
2 ... 32767
reserved
6.1.2.4
Object 605C
h
: Disable operation option code
The parameter
disable operatio
n
option code
determines what action should be taken if there
is a transition OPERATION ENABLE
⇒
SW ITCHED ON .
OBJECT DESCRIPTION
INDEX
605Ch
Name
Disable operation option code
Object Code VAR
Data Type
INTEGER16
Category
Optional
ENTRY DESCRIPTION
Access
rw
PDO Mapping No
Value Range
INTEGER16
Default Value 1
DATA DESCRIPTION
Value
Description
-32768 ... -1 manufacturer specific
0
Disable drive function
1
Slow down with slow down ramp and then disabling of the drive
function
2 ... 32767
reserved
Содержание MDC 100 30 6.5
Страница 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Страница 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Страница 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Страница 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Страница 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Страница 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...
Страница 57: ...www runcheng net www runcheng net...