4.8 Hybrid Cable: lengths and cross sections
Hybrid cable: Power Motor line and Signal (Ethernet Cat. 6)
Model
HYBCA – PSI
Max.
Voltage
Max.
Current
DC bus
Section
4mm
2
(x2)
(12AWG)
750VDC
20Arms
PE
Section
4mm
2
(x1)
(12AWG)
-
-
AUX. supply
Section
4mm
2
(x2)
(12AWG)
48VDC
20Arms
Total Maximum length
100 m
Communication
BUS
Section
0.2mm
2
(x2x4)
(24AWG)
Conductor resistance
4.95
Ω/km
Conductor resistance
91 Ω/km
Cable capacitance
50nF/km
Minimum bending radius
: 5 x diameter, fixed laying (PF
5x16=80mm);
10 x diameter, dynamic laying (PM
10x16=160mm).
4.9
Limits Hybrid cable with Intercontec connector
Power Motor
DC BUS
Vdc
750
Max current
A
20A
Main Power supply (@ 400Vac)
-
10kW on DC bus
up to 28 MDC60 @ nominal power
up to 14 MDC70 @ nominal power
up to 6 MDC100 @ nominal power
Main Power supply (@ 230Vac)
-
6kW on DC bus
up to 16 MDC60 @ nominal power
up to 8 MDC70 @ nominal power
up to 3 MDC100 @ nominal power
Control Supply
Auxiliary supply
Vdc
A
48
20
Содержание MDC 100 30 6.5
Страница 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Страница 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Страница 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Страница 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Страница 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Страница 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...
Страница 57: ...www runcheng net www runcheng net...