Parker Hannifin Manufacturing Srl
user’s manual MDC
39
OBJECT DESCRIPTION
INDEX
6040h
Name
Controlword
Object Code VAR
Data Type
UNSIGNED16
Category
Mandatory
ENTRY DESCRIPTION
Access
rw
PDO Mapping Possible
Value Range
UNSIGNED16
Default Value No
DATA DESCRIPTION The bits of the
controlword
are defined as follows:
15
11 10
9
8
7
6
4
3
2
1
0
Manufacture
r specific
Reserve
d
Hal
t
Faul
t
reset
Operatio
n mode
specific
Enable
operatio
n
Quic
k
stop
Enabl
e
voltag
e
Switc
h on
O
O
O
M
O
M
M
M
M
MSB
LSB
0 -Optional
M –Mandatory
BITS 0 – 3 AND 7:
Device control commands are triggered by the following bit patterns in the
controlword
:
Command
Bit of the controlword
Transitions
Fault
reset
Enable
operation
Quick stop
Enable
voltage
Switch on
Shutdown
0
X
1
1
0
2,6,8
Switch on
0
0
1
1
1
3*
Switch on
0
1
1
1
1
3**
Disable
voltage
0
X
X
0
X
7,9,10,12
Quick stop
0
X
0
1
X
7,10,11
Disable
operation
0
0
1
1
1
5
Enable
operation
0
1
1
1
1
4,16
Fault reset
X
X
X
X
15
Table 4: Device control commands
(bits marked X are irrelevant, * ... In the state
SWITCHED ON the drive executes the functionality of this state., ** ... It exists no
functionality in the state SWITCHED ON. The drive does not do any in this state.)
Содержание MDC 100 30 6.5
Страница 1: ...User s manual Rev 0 1 August 2012 MDC MotorNet DC www runcheng net www runcheng net...
Страница 13: ...Parker Hannifin Manufacturing Srl user s manual MDC 13 3 3 Motor data...
Страница 16: ...Parker Hannifin Manufacturing Srl user s manual MDC 16...
Страница 17: ...Parker Hannifin Manufacturing Srl user s manual MDC 17...
Страница 18: ...Parker Hannifin Manufacturing Srl user s manual MDC 18...
Страница 22: ...Parker Hannifin Manufacturing Srl user s manual MDC 22 4 5 Hybrid cable Connection PSI MDC...
Страница 57: ...www runcheng net www runcheng net...