Installation and servicing manual

Air Oil Coolers, LOC

 

18

Parker Hannifin Corporation

Hydraulics Group

Catalogue HY10-6003-UM/EU

Dismounting the pump and coupling

1. Turn off the system.

2. Disconnect the power supply.

3. Make sure that the system is de-pressurized.

4. Disconnect the oil inlets and outlets.

5. Disconnect the hydraulic hoses from the cooler matrix.

6.  Remove the screws and rubber steel washers fixing the pump 

to the electric motor.

7.  Remove the pump and the gear ring of the coupling. 

The pump and the coupling parts can now be replaced.

8.  Loosen the stop screw of the shaft coupling part. 

Remove the shaft coupling part from the crankshaft.

Mounting of the pump and coupling

1.  Fit the shaft coupling part to the crankshaft. 

Tighten the stop screw.

2. Install the pump and gear ring of the coupling.

3.  Install the screws and rubber steel washer fixing the pump to 

the electric motor.

4. Connect the hydraulic hoses. 

See Figure 4

.

5. Connect the electric motor power supply.

6. Proceed to Prior to start-up and At start-up.

Dismounting the electric motor and fan

  

Caution

 Risk of severe burns. As the cooling system 

could become extremely hot during operation, make sure 

the system is cool before touching.

 

 Precaution

 Risk of bodily harm. Prior to maintenance, 

disconnect the electric motor power supply. The fan is 

balanced together with the hub prior to delivery.

The fan is balanced together with the hub at delivery.

Note! 

There are models with fixed hub 

Figure 10

 and models with 

detachable hub 

Figure 11 A and Figure 11 B.

1. Turn off the system.

2.  Dismount the pump according to Dismounting the pump and 

coupling.

3. Secure the motor.

4.  Unscrew the screws with washers fixing the motor attachment 

to the fan housing. 

See Figure 9.

5.  Unscrew the screws with washers fixing the motor support to 

the feet. Pull the motor backwards.

6.  Unscrew the screw with washer fixing the fan/hub to the 

crankshaft. 

See Figure 10.

 Remove with care the fan/hub from 

the crankshaft. Use a pulley if required.

7.  Unscrew the screws with washers fixing the motor to the motor 

attachment. 

See Figure 12.

8.  Unscrew the screws with washers fixing the motor to the motor 

bracket.

9. Remove the motor.
If further dismounting of the fan is required, label all parts to ensure 

correct assembly, first of all with regard to balance and direction of 

rotation. 

See Figure 13.

Mounting of the electric motor and fan
Note! 

There are models with fixed hub 

Figure 10 a

nd models with 

detachable hub

 Figure 11 A and Figure 11 B.

1. Fit the motor to the motor bracket.

2.  Fit the motor to the motor attachment by screws. 

See Figure 12.

3.  Fit the hub groove to the motor spline. Lube the hub with 

ethanol and secure the fan with hub to the cranks haft. If 

required, knock carefully with e.g. a rubber mal let. Use Loctite 

on the screw and secure the fan with hub on the crankshaft by 

screws. 

See Figure 10.

4.  Make sure that the fan is fitted to the crankshaft without too 

much play.

5.  Place the motor attachment with fan, fan guard, motor and 

motor support in the fan housing.

6.  Adjust the fan guard and motor and fix the motor attachment 

onto the fan housing by screws.

 See Figure 9.

 

Secure the motor support by screws.

7.  Make sure the fan is centred/aligned and rotates freely 

(use hand force). If necessary, adjust the location of the fan 

guard and motor.

8. Make sure all screws are tightened.

9. Connect the electric motor power supply.

10.Proceed to Prior to start-up and At start-up.

Oil filter unit FX3

Fitted with an filter unit type FX3 the oil will be cleaned in a sepa-

rate system. This is an excellent complement to the system oil 

cleaning system. Filter unit FX3 is available as option.

Prior to start-up

1.  Bleed filter by opening the vent plug at the top of filter approx-

imately two turns.

2. Fill filter until all air bleeds through the plug, then tighten plug.

3.  Pressurize system fully and check for leaks; if leaks occur refer 

to Routine maintenance.

 

 Precaution

 Failure to bleed the filter unit adequately will 

increase the dissolved air content of the system oil, which 

will shorten oil life and may cause other problems in the 

system.

Routine maintenance

The filter unit FX3 does not normally require special attention 

except for periodic monitoring of the pressure drop indicator. 

Schedule replacement of filter element every six months or sooner, 

and have ample supply of spare elements available.

 

 Caution

 Failure to depressurize the filter unit before servi-

cing element may result in personnel injury or damage to 

property, or environment.

Maintenance

Содержание LOC

Страница 1: ...oolers LOC Cooling System for industrial Use Installation and servicing manual aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing s...

Страница 2: ...rvicing manual Air Oil Coolers LOC 2 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6003 UM EU Catalogue HY10 6003 UM EU AIR OIL COOLER LOC AIR OIL COOLER LOC 1 5 4 13 2 A 1 2 A B B 1 2 A...

Страница 3: ...Group Catalogue HY10 6003 UM EU 6 Y koppling Y connection Y Anschluss Connexion en Y Conexi n en Y D koppling D connection D Anschluss Connexion en D Conexi n en D Y koppling Y connection Y Anschluss...

Страница 4: ...tallation and servicing manual Air Oil Coolers LOC 4 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6003 UM EU AIR OIL COOLER LOC AIR OIL COOLER LOC AIR OIL COOLER LOC 11 A 12 10 9 11 B 7...

Страница 5: ...lexible hidr ulico con conexiones J Consola del motor K Bomba El asiento del ventilador fijo o desmontable depender del tipo de sistema de refrigeraci n A B C D E F G H I J K Komponentf rteckning A El...

Страница 6: ...ositivo de presi n diferencial I Conjunto filtro Disponible como bypass controlado por pre ci n o por temperatura y presi n Accesorios A C ncamos de elevaci n G Silent blocs Tillval B S Bypass enpassa...

Страница 7: ...17 Technical specification 20 Declaration of conformity 21 Einleitung 22 Sicherheitsvorschriften 22 Beschreibung 23 Installation 23 Bedienung 24 Vorbeugende Wartung 24 Wartung 25 Technische Daten 27 K...

Страница 8: ...gt f ljande Anm Anger extra information som kan underl tta f rst else f r eller utf rande av ett visst moment vergripande f reskrifter Lyft Varning Kl m krossrisk F r att undvika personskador vid lyft...

Страница 9: ...der tankens v tskeniv max 5 meter och s n ra tanken som m jligt Vid montering ovanf r tankens v tskeniv skall h jdskillnaden minimeras Inloppsledningens diameter b r inte vara mindre n pumpens anslutn...

Страница 10: ...den elektriska installationen Detta f r en dast utf ras av beh rig elektriker Pumpen r under normala driftsf rh llanden underh llsfri Drift under extrema f rh llanden kr ver inspektion och underh ll e...

Страница 11: ...g av fl kt m rk upp alla delarna f r att s kerst lla korrekt termontering framf rallt med avseende p balans och rotationsriktning Se Bild 13 Montering av elmotor och fl kt Anm Vissa modeller har fast...

Страница 12: ...mt byt filterpatron Indikator typ M Den elektriska tryckfallsindikatorn M har automatisk terst ll ning och anslutning enligt DIN 43650 ISO4400 Hirschmann och r fukts ker enligt IP65 F r effektiv verva...

Страница 13: ...or Vegetabiliska oljor Vid drift med andra v tskor eller vid extrema driftsf rh llanden kontakta Parker Material Pumphus Kylelement Aluminium Filterenhet tillval Aluminium Fl kthus St l Fl ktblad nav...

Страница 14: ...20 Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fi...

Страница 15: ...the text in a paragraph Overall instructions Lifting Caution Risk of bodily injury To prevent physical harm when lifting the unit ensure correct lifting technique is used Make sure that all lifting de...

Страница 16: ...line Maximum pressure on the pump suction side is 0 5 bar Electrical connection Danger Electrical shock hazard All electrical connections must be made by a qualified electrician Prior to connecting t...

Страница 17: ...bodily injury Prior to cleaning disconnect all motor power supplies Caution Risk of severe burns As the cooling system could become extremely hot during operation make sure the system is cool before t...

Страница 18: ...emove the motor If further dismounting of the fan is required label all parts to ensure correct assembly first of all with regard to balance and direction of rotation See Figure 13 Mounting of the ele...

Страница 19: ...light comes on during cold tart continue operating until the signal red light goes out as system warms to normal opera ting temperature This feature can be used as warm up indication in operating proc...

Страница 20: ...use with other oils or operation in extreme conditions contact your local Parker office Material Pump housing Cooler matrix Aluminium Filter unit option Aluminium Fan housing Steel Fan blades hub Glas...

Страница 21: ...Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin...

Страница 22: ...hren und sonstigen Sicherheit Hinweistexte zur sonstigen Sicherheit Gegenst nde Prozesse oder Umfeld und Bedienung sind wie folgt unterteilt Wichtig weist darauf hin dass ein Unfall sich ereignen kann...

Страница 23: ...es nicht m glich ist installieren Sie am Ein und Austritt des Systems ein R ckschlag oder Absperrventil Anschluss des K hlsystems Der Anschluss des K hlsystems erfolgt mittels Hydraulikschl uchen Sich...

Страница 24: ...der maximale Pumpendruck berschritten wird Dies kann eintreten wenn das System auf der Druckseite abgeschaltet oder sehr stark gedrosselt wird Siehe Produktbrosch re der QPM Niederdruckpumpe Dies kann...

Страница 25: ...errad wurde vor der Auslieferung zusammen mit der Nabe ausgewuchtet Hinweis Einige Modelle haben eine starre Nabe siehe Abb 10 Bei anderen Modellen ist die Nabe lose Abb 11 A und Abb 11 B 1 Die Anlage...

Страница 26: ...43650 ISO4400 Sie ist nach Schutzklasse IP65 feuchtigkeitsfest Zur berwachung des Filterelements empfiehlt es sich zwei Anzeigeleuchten vorzusehen die positive Anzeige zur Unver sehrtheit des Filters...

Страница 27: ...Betriebs mit anderen len oder unter erschwerten Bedingungen wenden Sie sich an Parker Material Pumpengeh use K hlelement Aluminium Filtereinheit optional Aluminium L ftergeh use Stahl L fterrad Nabe G...

Страница 28: ...afety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin Ma...

Страница 29: ...la s curit biens proc d ou environnement et l entretien du syst me de refroidissement sont class s comme suit Important indique qu un accident peut se produire en cas de nonrespect des consignes Cet...

Страница 30: ...t Contactez Parker Pour viter que le r servoir ne se vide pendant le remplacement de l l ment filtrant le niveau d huile du syst me LOC doit tre au dessus du niveau du fluide du r servoir Si cela n es...

Страница 31: ...as toucher avant qu il n ait refroidi Remarque Pour tout s jour prolong proximit d un syst me de refroidissement en fonctionnement portez un casque antibruit Avertissement Le syst me LOC ne doit pas t...

Страница 32: ...teur Serrez la vis d arr t 2 Posez la pompe et la couronne du raccord 3 Posez les vis et les joints l vres qui fixent la pompe au moteur lectrique 4 Connectez les flexibles hydrauliques Voir la Figure...

Страница 33: ...ments filtrants peuvent tre n cessaires avant d obtenir une dur e de vie stabilis e Si la dur e de vie de l l ment filtrant est trop courte ou si la pression diff rentielle est excessive il est possib...

Страница 34: ...s 9 Serrez le bouchon de vidange lorsque l huile sort du filtre Au d marrage il est possible que l indicateur se d clenche cause d une viscosit trop lev e R enclenchez le Ne faites pas fonctionner le...

Страница 35: ...d autres huiles ou d une utilisation dans des conditions extr mes Mat riaux Corps de pompe radiateur Aluminium Filtre option Aluminium Caisson de ventilateur Acier H lice moyeu Polypropyl ne renforc f...

Страница 36: ...Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin...

Страница 37: ...lizado inco rrectamente puede provocar da os en el equipo al proceso o al medio ambiente relativos a las inf rmaciones complementarias Las informaciones complementarias est n indicadas como sigue Nota...

Страница 38: ...seg rese de que el nivel de aceite del sistema LOC es superior al nivel del dep sito Si esto no fuera posible instale una v lvula de control o de cierre en la entrada y la salida del sistema Conexi n...

Страница 39: ...friarse Nota Para un trabajo prolongado cerca de un sistema LOC en funcionamiento se deben utilizar cascos o tapones anti ruido Advertencia El sistema LOC no puede ser utilizarse en aquellas condicion...

Страница 40: ...del acoplamiento 3 Fijar los tornillos y las arandelas de acero goma que fijan la bomba al motor el ctrico 4 Conectarlos flexibles hidr ulicos Ver fig 4 5 Conectar la fuente de alimentaci n del motor...

Страница 41: ...e existe tiempo suficiente disponible para cambiar el cartucho del filtro antes de que la v lvula by pass se abra permitiendo el paso de aceite no filtrado igualmente maximiza la vida til del elemento...

Страница 42: ...es cribe en el apartado Dispositivos de presi n diferencial Parker no garantiza la vida til del elemento filtrante ya que ex cede al control del vendedor y depende de las condiciones del sistema en el...

Страница 43: ...ites o para el funcionamiento bajo condiciones extremas contacte con su empresa Material Carcasa de la bomba Radiador Aluminio Conjunto filtro opcional Aluminio Caja del ventilaor Acero Helices asient...

Страница 44: ...0 Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin...

Страница 45: ...Installation and servicing manual Air Oil Coolers LOC 45 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6003 UM EU...

Страница 46: ...r com PT Portugal Leca da Palmeira Tel 351 22 999 7360 parker portugal parker com RO Romania Bucharest Tel 40 21 252 1382 parker romania parker com RU Russia Moscow Tel 7 495 645 2156 parker russia pa...

Отзывы: