Installation and servicing manual

Air Oil Coolers, LOC

 

16

Parker Hannifin Corporation

Hydraulics Group

Catalogue HY10-6003-UM/EU

Installation/Handling

Installation

Lifting
 

 Caution

 Risk of bodily injury. To prevent bodily injury when 

lifting the unit, ensure correct lifting technique is used. 

Make sure that all lifting devices are working properly and 

approved for the weight of the cooling system.

The LOC cooling system as from size 033 can accommodate 

lifting eyes. Lifting eyes are available from Parker on request.

Mounting
 

 Precaution 

Risk of bodily injury. Make sure that all parts of 

the cooling system are firmly secured.

An upright installation of the cooling system standing on its feet is re-

commended. To prevent bodily injury, make sure the cooling system 

is securely fixed.

A free space corresponding to a minimum of half the height of the 

matrix should be available in front of and behind the cooling system 

to allow for good airflow, i.e. optimal cooling capacity as well as low 

acoustic pressure level. 

See Figure 3.

In cases where a filter unit is provided, a space corresponding to at 

least the size of the filter element should be available above the filter 

unit to allow for replacement of the filter element. 

See Figure 3.

The acoustic pressure could reach 57-86 dB(A) LpA at 1 m distance 

in normal operating conditions. Inappropriate location of the cooling 

system or operation in extreme conditions could generate increased 

acoustic pressure and reduce cooling capacity. Consult your local 

Parker office.

In order to avoid that the tank empties when replacing the filter ele-

ment, make sure that the cooling system oil level is above that of the 

tank. If this is not possible, install a control valve or shut-off valve in 

the system inlet and outlet.

Connection of the cooling system

Connect the cooling system using flexible hydraulic hoses to the 

hydraulic system. Make sure that all connections and hoses are 

sized according to the system pressure, flow, temperature and 

type of oil. Connect the hydraulic hoses as illustrated in 

Figure 4

A

 – Inlet. 

B

 – Outlet for S by-pass, single-pass.

C

 -  Outlet for T by-pass, two-pass.

D

 - Connection for thermo contact

The sizes of connections are cooling system dependent.
Maximum permitted oil temperature is 100°C.
Flow chart, 

see Figure 5

.

To achieve the very best pump capacity, place the cooling system 

below tank oil level (max. 5 meter) and as close to the tank as 

possible. When installed above tank oil level, minimize the difference 

in height. The size of the inlet line should not be inferior to the pump 

connection size. A larger size is recommended.

Avoid flow rates in excess of 1 m/s in the pump inlet line.

Maximum pressure on the pump suction side is 0.5 bar.

Electrical connection

  

Danger

 Electrical shock hazard. All electrical connections 

must be made by a qualified electrician!

Prior to connecting the motor to the electrical supply system, make 

sure the specification on the electric motor rating plate corresponds 

to the mains supply voltage and frequency. The electric motor 

should be installed according to general rules and electrical safety 

regulations and must be installed by a qualified electrician.

 

 Caution

 Be careful when connecting the equipment. 

Improperly made connections, damaged cables, etc. 

could cause parts to become current carrying or result in 

incorrect direction of rotation of the electric motor, fan and 

pump. 

See Figure 6.

Important

 Do not exceed the maximum rated current for the 

electric motor, 

see electric motor rating plate

.

Note!

 An electric motor overload protection is recommended. 

In extremely humid environments, especially when the operation is 

intermittent, water condensation could build up. Some motors are 

fitted with plugged holes, which can be used to drain condense 

water. Depending on the placement of the electric motor, proper 

plugs should be removed.

LOC cooling system can be provided with a thermo contact for 

temperature control. The fan will start automatically when the pre-

set temperature has been reached. Use a relay if the current load 

exceeds the maximum load for the thermo contact.

Note! 

The thermo contact may not be used for direct control of the 

electric motor.

Handling

Prior to initial start-up
 

 Precaution

 Make sure the cooling system is securely fixed 

and correctly connected.

We recommend the following prior to initial start-up:

1.  Run the cooling system with the same oil as used in the hydraulic 

system.

2. Filter the oil before passing through the cooling system.

See Technical specification for oil compatibility.

Prior to start up
 

 Precaution

 Make sure that the unit can be put into service 

without causing bodily injury or damage to property or 

environment. 

Make sure that:

• the fan rotates freely (use hand force)

• all oil linlets and outlets are tight

•  the inside of the fan housing is free from objects that could be 

thrown around and cause bodily injury or damage to property

•  valves and similar throttling devices are open and that conduits 

and couplings are not damaged.

•  valves and similar throttling devices are open and that conduits 

and couplings are not damaged.

At start-up

 

Make sure that:

•  the direction of rotation of the fan and the airflow corresponds to 

indications on the fan housing,

•  the cooling system is free from abnormal noise and vibrations,

• the cooling system is free from leaks.
Make sure not to overload the electric motor due to cold start 

conditions or operation with high oil viscosity. Viscosity range is 

10 – 800 cSt considering the pump, motor power, filter element 

size etc.

Содержание LOC

Страница 1: ...oolers LOC Cooling System for industrial Use Installation and servicing manual aerospace climate control electromechanical filtration fluid gas handling hydraulics pneumatics process control sealing s...

Страница 2: ...rvicing manual Air Oil Coolers LOC 2 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6003 UM EU Catalogue HY10 6003 UM EU AIR OIL COOLER LOC AIR OIL COOLER LOC 1 5 4 13 2 A 1 2 A B B 1 2 A...

Страница 3: ...Group Catalogue HY10 6003 UM EU 6 Y koppling Y connection Y Anschluss Connexion en Y Conexi n en Y D koppling D connection D Anschluss Connexion en D Conexi n en D Y koppling Y connection Y Anschluss...

Страница 4: ...tallation and servicing manual Air Oil Coolers LOC 4 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6003 UM EU AIR OIL COOLER LOC AIR OIL COOLER LOC AIR OIL COOLER LOC 11 A 12 10 9 11 B 7...

Страница 5: ...lexible hidr ulico con conexiones J Consola del motor K Bomba El asiento del ventilador fijo o desmontable depender del tipo de sistema de refrigeraci n A B C D E F G H I J K Komponentf rteckning A El...

Страница 6: ...ositivo de presi n diferencial I Conjunto filtro Disponible como bypass controlado por pre ci n o por temperatura y presi n Accesorios A C ncamos de elevaci n G Silent blocs Tillval B S Bypass enpassa...

Страница 7: ...17 Technical specification 20 Declaration of conformity 21 Einleitung 22 Sicherheitsvorschriften 22 Beschreibung 23 Installation 23 Bedienung 24 Vorbeugende Wartung 24 Wartung 25 Technische Daten 27 K...

Страница 8: ...gt f ljande Anm Anger extra information som kan underl tta f rst else f r eller utf rande av ett visst moment vergripande f reskrifter Lyft Varning Kl m krossrisk F r att undvika personskador vid lyft...

Страница 9: ...der tankens v tskeniv max 5 meter och s n ra tanken som m jligt Vid montering ovanf r tankens v tskeniv skall h jdskillnaden minimeras Inloppsledningens diameter b r inte vara mindre n pumpens anslutn...

Страница 10: ...den elektriska installationen Detta f r en dast utf ras av beh rig elektriker Pumpen r under normala driftsf rh llanden underh llsfri Drift under extrema f rh llanden kr ver inspektion och underh ll e...

Страница 11: ...g av fl kt m rk upp alla delarna f r att s kerst lla korrekt termontering framf rallt med avseende p balans och rotationsriktning Se Bild 13 Montering av elmotor och fl kt Anm Vissa modeller har fast...

Страница 12: ...mt byt filterpatron Indikator typ M Den elektriska tryckfallsindikatorn M har automatisk terst ll ning och anslutning enligt DIN 43650 ISO4400 Hirschmann och r fukts ker enligt IP65 F r effektiv verva...

Страница 13: ...or Vegetabiliska oljor Vid drift med andra v tskor eller vid extrema driftsf rh llanden kontakta Parker Material Pumphus Kylelement Aluminium Filterenhet tillval Aluminium Fl kthus St l Fl ktblad nav...

Страница 14: ...20 Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fi...

Страница 15: ...the text in a paragraph Overall instructions Lifting Caution Risk of bodily injury To prevent physical harm when lifting the unit ensure correct lifting technique is used Make sure that all lifting de...

Страница 16: ...line Maximum pressure on the pump suction side is 0 5 bar Electrical connection Danger Electrical shock hazard All electrical connections must be made by a qualified electrician Prior to connecting t...

Страница 17: ...bodily injury Prior to cleaning disconnect all motor power supplies Caution Risk of severe burns As the cooling system could become extremely hot during operation make sure the system is cool before t...

Страница 18: ...emove the motor If further dismounting of the fan is required label all parts to ensure correct assembly first of all with regard to balance and direction of rotation See Figure 13 Mounting of the ele...

Страница 19: ...light comes on during cold tart continue operating until the signal red light goes out as system warms to normal opera ting temperature This feature can be used as warm up indication in operating proc...

Страница 20: ...use with other oils or operation in extreme conditions contact your local Parker office Material Pump housing Cooler matrix Aluminium Filter unit option Aluminium Fan housing Steel Fan blades hub Glas...

Страница 21: ...Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin...

Страница 22: ...hren und sonstigen Sicherheit Hinweistexte zur sonstigen Sicherheit Gegenst nde Prozesse oder Umfeld und Bedienung sind wie folgt unterteilt Wichtig weist darauf hin dass ein Unfall sich ereignen kann...

Страница 23: ...es nicht m glich ist installieren Sie am Ein und Austritt des Systems ein R ckschlag oder Absperrventil Anschluss des K hlsystems Der Anschluss des K hlsystems erfolgt mittels Hydraulikschl uchen Sich...

Страница 24: ...der maximale Pumpendruck berschritten wird Dies kann eintreten wenn das System auf der Druckseite abgeschaltet oder sehr stark gedrosselt wird Siehe Produktbrosch re der QPM Niederdruckpumpe Dies kann...

Страница 25: ...errad wurde vor der Auslieferung zusammen mit der Nabe ausgewuchtet Hinweis Einige Modelle haben eine starre Nabe siehe Abb 10 Bei anderen Modellen ist die Nabe lose Abb 11 A und Abb 11 B 1 Die Anlage...

Страница 26: ...43650 ISO4400 Sie ist nach Schutzklasse IP65 feuchtigkeitsfest Zur berwachung des Filterelements empfiehlt es sich zwei Anzeigeleuchten vorzusehen die positive Anzeige zur Unver sehrtheit des Filters...

Страница 27: ...Betriebs mit anderen len oder unter erschwerten Bedingungen wenden Sie sich an Parker Material Pumpengeh use K hlelement Aluminium Filtereinheit optional Aluminium L ftergeh use Stahl L fterrad Nabe G...

Страница 28: ...afety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin Ma...

Страница 29: ...la s curit biens proc d ou environnement et l entretien du syst me de refroidissement sont class s comme suit Important indique qu un accident peut se produire en cas de nonrespect des consignes Cet...

Страница 30: ...t Contactez Parker Pour viter que le r servoir ne se vide pendant le remplacement de l l ment filtrant le niveau d huile du syst me LOC doit tre au dessus du niveau du fluide du r servoir Si cela n es...

Страница 31: ...as toucher avant qu il n ait refroidi Remarque Pour tout s jour prolong proximit d un syst me de refroidissement en fonctionnement portez un casque antibruit Avertissement Le syst me LOC ne doit pas t...

Страница 32: ...teur Serrez la vis d arr t 2 Posez la pompe et la couronne du raccord 3 Posez les vis et les joints l vres qui fixent la pompe au moteur lectrique 4 Connectez les flexibles hydrauliques Voir la Figure...

Страница 33: ...ments filtrants peuvent tre n cessaires avant d obtenir une dur e de vie stabilis e Si la dur e de vie de l l ment filtrant est trop courte ou si la pression diff rentielle est excessive il est possib...

Страница 34: ...s 9 Serrez le bouchon de vidange lorsque l huile sort du filtre Au d marrage il est possible que l indicateur se d clenche cause d une viscosit trop lev e R enclenchez le Ne faites pas fonctionner le...

Страница 35: ...d autres huiles ou d une utilisation dans des conditions extr mes Mat riaux Corps de pompe radiateur Aluminium Filtre option Aluminium Caisson de ventilateur Acier H lice moyeu Polypropyl ne renforc f...

Страница 36: ...Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin...

Страница 37: ...lizado inco rrectamente puede provocar da os en el equipo al proceso o al medio ambiente relativos a las inf rmaciones complementarias Las informaciones complementarias est n indicadas como sigue Nota...

Страница 38: ...seg rese de que el nivel de aceite del sistema LOC es superior al nivel del dep sito Si esto no fuera posible instale una v lvula de control o de cierre en la entrada y la salida del sistema Conexi n...

Страница 39: ...friarse Nota Para un trabajo prolongado cerca de un sistema LOC en funcionamiento se deben utilizar cascos o tapones anti ruido Advertencia El sistema LOC no puede ser utilizarse en aquellas condicion...

Страница 40: ...del acoplamiento 3 Fijar los tornillos y las arandelas de acero goma que fijan la bomba al motor el ctrico 4 Conectarlos flexibles hidr ulicos Ver fig 4 5 Conectar la fuente de alimentaci n del motor...

Страница 41: ...e existe tiempo suficiente disponible para cambiar el cartucho del filtro antes de que la v lvula by pass se abra permitiendo el paso de aceite no filtrado igualmente maximiza la vida til del elemento...

Страница 42: ...es cribe en el apartado Dispositivos de presi n diferencial Parker no garantiza la vida til del elemento filtrante ya que ex cede al control del vendedor y depende de las condiciones del sistema en el...

Страница 43: ...ites o para el funcionamiento bajo condiciones extremas contacte con su empresa Material Carcasa de la bomba Radiador Aluminio Conjunto filtro opcional Aluminio Caja del ventilaor Acero Helices asient...

Страница 44: ...0 Safety dista N ISO 1385 s for liquids on the produ lectromagn lete produc n Manufact complete b ker Hannifin been declar __________ ard Eriksso chnical Man rker Hannifi a Box 8064 1 claration of fin...

Страница 45: ...Installation and servicing manual Air Oil Coolers LOC 45 Parker Hannifin Corporation Hydraulics Group Catalogue HY10 6003 UM EU...

Страница 46: ...r com PT Portugal Leca da Palmeira Tel 351 22 999 7360 parker portugal parker com RO Romania Bucharest Tel 40 21 252 1382 parker romania parker com RU Russia Moscow Tel 7 495 645 2156 parker russia pa...

Отзывы: