Associated Equipment - Power Stack
6-3
AC30 series Variable Speed Inverter
Circuit Breakers (alternative to AC Line Fuses)
We do not recommend the use of circuit breakers (e.g. RCD, ELCB, GFCI), but where their use is mandatory, they should:
•
Operate correctly with dc and ac protective earth currents (i.e. type B RCDs as in Amendment 2 of IEC755).
•
Have adjustable trip amplitude and time characteristics to prevent nuisance tripping on switch-on.
When the ac supply is switched on, a pulse of current flows to earth to charge the internal/external ac supply EMC filter’s internal
capacitors which are connected between phase and earth. This has been minimised in Parker inverter filters, but may still trip out any
circuit breaker in the earth system. In addition, high frequency and dc components of earth leakage currents will flow under normal
operating conditions. Under certain fault conditions larger dc protective earth currents may flow. The protective function of some circuit
breakers cannot be guaranteed under such operating conditions.
WARNING
Circuit breakers used with VSDs and other similar equipment are not suitable for personnel protection. Use other means to provide
personal safety. Refer to EN50178 / VDE0160 / EN60204-1.
External EMC Filters (optional)
Additional external EMC filters are sometimes required to meet specific conducted emissions standards and environments.
Parker recommend Roxburgh KMFA series ‘High performance three phase industrial mains filters for drives applications’ for use with the
AC30 series power stacks.
Refer to ‘Appendix A: Compliance’ for further information on when an external EMC filter is to be used, as well as EMC advice to
consider during the product installation.
Содержание LINKnet AC30P
Страница 4: ...AC30 series Variable Speed Inverter...
Страница 16: ...2 4 Introduction AC30 series Variable Speed Inverter...
Страница 22: ...3 6 Product Overview AC30 series Variable Speed Inverter...
Страница 49: ...Installation Control Module 5 11 AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Страница 51: ...Installation Control Module 5 13 AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Страница 55: ...Installation Control Module 5 17 AC30 series Variable Speed Inverter Presets Speeds Wiring...
Страница 57: ...Installation Control Module 5 19 AC30 series Variable Speed Inverter PID Control Wiring...
Страница 68: ...5 30 Installation Control Module AC30 series Variable Speed Inverter...
Страница 82: ...6 14 Associated Equipment Power Stack AC30 series Variable Speed Inverter...
Страница 86: ...7 4 Associated Equipment Control Module AC30 series Variable Speed Inverter...
Страница 124: ...9 8 The Graphical Keypad AC30 series Variable Speed Inverter...
Страница 126: ...10 2 Routine Maintenance Repair AC30 series Variable Speed Inverter...
Страница 152: ...A 26 Compliance AC30 series Variable Speed Inverter...
Страница 166: ...E 8 Technical Specifications Power Stack AC30 series Variable Speed Drive...
Страница 175: ...AC30 series Variable Speed Drive...