Chapter 5 – Troubleshooting
63
Motor Problems
Verify that the drive is configured properly for the motor you are using. The motor
series, frame size, and part number information on a Compumotor motor’s name
plate should match the settings stored in the drive’s memory.
Motor Brake
If you are using a motor with a brake, verify that the brake is connected properly,
and that it is functioning as intended.
Motor Resolver
Resolvers on Compumotor motors are aligned at the factory. Ordinarily, no further
alignment is necessary. However, if you suspect that the resolver has been altered
and is out of alignment, you can follow the alignment procedure in
Aligning the
Resolver
, located in
Chapter 4 Special Features
.
Mechanical System
Shaft Coupler
Verify that the shaft coupler is not slipping during acceleration or deceleration. We
recommend bellows or disk style couplers for servo applications; helical couplers
are inadequate, and are
not
recommended.
Mechanical Transmission
Verify that your mechanical system functions properly, and is not jammed.
Motion Problems
If problems occur during motion, check these possible causes:
•
Motor Sizing (ensure that the motor has enough torque to perform the move)
•
Excessive Acceleration or Deceleration
•
Excessive Velocity
Electrical Noise
Electrical noise on input or output lines can cause stop or kill inputs to activate
unexpectedly. See
Appendix C: Regulatory Compliance
for installation guidelines
on reducing electrical noise.
Software/Motion Program Problems
Check to see that your motion programs are functioning properly, and are not
causing unexpected problems.