Chapter 4 – Special Features
41
Gem6K Drive
Gem6K Drive
Gem6K Drive
For multiple drives, use a
single point safety earth
Multiple Drives: Single Point Safety Earth
Under normal operation, no current should flow through the safety earth connec-
tion.
Connecting V Bus
±
: Sharing the Power Bus (optional)
(GV6K-U3n/6n/12n/H40n only)
You can connect the power buses of GV6K-U3n/6n/12n/H40n drives in parallel,
through the V BUS+ and V BUS- terminals. With the buses connected in parallel,
regenerated energy from one drive will be used by the other drives. (Do
not
connect GV6-H20n drives in parallel to each other or to other GemK or Gemini
drives.)
WARNING
V BUS+ and V BUS- terminals are at hazardous voltages when power is applied to
the drive, and for up to 30 seconds after power is removed. Lower voltages may
still be present for several minutes after power is removed. Reinstall the clear
plastic terminal cover after you make connections.
CAUTION
Connect together only V BUS
±
terminals of drives that share the same fused AC
power source, as shown in the next drawing.