Parker EME
Mounting and dimensions
192-
120102N23 2016-04
19
Mains connection Compax3S0xxV2 1AC
Controller type
S025V2
S063V2
Continuous working voltage
Single phase 230VAC/240VAC
80-253VAC / 50-60Hz
Receiver current consumption
6Arms
13Arms
Maximum fuse rating per device
10 A (automatic
circuit breaker K)
16A (automatic circuit
breaker K)
Mains connection Compax3S1xxV2 3AC
Controller type
S100V2
S150V2
Supply voltage
Three phase 3* 230VAC/240VAC
80-253VAC / 50-60Hz
Input current
10Arms
13Arms
Maximum fuse rating per device
16A
20A
MCB miniature circuit breaker, K characteristic
Mains connection Compax3SxxxV4 3AC
Controller type
S015V4
S038V4
S075V4
S150V4
S300V4
Continuous working
voltage
Three phase 3*400VAC/480VAC
80-528VAC / 50-60Hz
Receiver current
consumption
3Aeff
6Arms
10Arms
16Arms
22Arms
Maximum fuse rating per
device
6A
10A
16A
20A
25A
MCB miniature circuit breaker, K characteristic
Control voltage 24VDC Compax3S and Compax3H
Controller type
Compax3
Voltage range
21 - 27VDC
Current drain of the device
0.8 A
Total current drain
0.8 A + Total load of the digital o current
for the motor holding brake
Ripple (max.)
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes
Short-circuit proof
conditional (internally protected with 3.15AT)
Cable length
< 30 m
Detailed information on the technical data of the Compax3 devices can be
found in the Help- or PDF-files of the individual Compax3 device types.
4. Technical Data