Parker EME
Conditions of utilization
192-
120102N23 2016-04
11
2.7.2.
Conditions of utilization for UL certification Compax3S
UL certification for Compax3S
conform to UL:
according to UL508C
Certified
E-File_No.: E235342
The UL certification is documented by a "UL" logo on the
device (type specification plate).
“UL” logo:
Conditions of utilization
The devices are only to be installed in a degree of contamination 2 environment
(maximum).
The devices must be appropriately protected (e.g. by a switching cabinet).
The X2 terminals are not suitable for field wiring.
Tightening torque of the field wiring terminals ( green Phoenix plugs)
C3S0xxV2
0.57 - 0.79Nm
5 - 7Lb.in
C3S1xxV2,
C3S0xxV4, C3S150V4
0.57 - 0.79Nm
5 - 7Lb.in
C3S300V4
1.25 - 1.7Nm
11 - 15Lb.in
Temperature rating of field installed conductors shall be at least 60°C. Use
copper lines only
Please use the cables described in the accessories chapter, they feature a
temperature rating of at least 60°C.
Maximum Surrounding Air Temperature: 45°C.
Motor over temperature monitoring is only supported, if the external temperature
sensor is connected.
Suitable for use on a circuit capable of delivering at least 5000 symmetrical
amperes effectively and 480 Volts when protected with fuses.
Fuses:
In addition to the main fuse, the devices must be equipped with a S201K, S203K,
S271K or S273K circuit breaker with K characteristic made by ABB.
C3S025V2: ABB, nom 480V 10A, 6kA
C3S063V2: ABB, nom 480V, 16A, 6kA
C3S100V2: ABB, nom 480V, 16A, 6kA
C3S150V2: ABB, nom 480V, 20A, 6kA
C3S015V4: ABB, nom 480V, 6A, 6kA
C3S038V4: ABB, nom 480V, 10A, 6kA
C3S075V4: ABB, nom 480V, 16A, 6kA
C3S150V4: ABB, nom 480V, 20A, 6kA
C3S300V4: ABB, nom 480V, 25A, 6kA
CAUTION
Risk of electric shock.
Discharge time of the bus capacitor is 15 minutes.
The drive provides internal motor overload protection.
This must be set so that 200% of the motor nominal current are not exceeded.
Cable cross-sections
Mains input: corresponding to the recommended fuses.
Motor cable: corresponding to the Nominal output currents
Maximum cross-section limited by the terminals mm
2
/ AWG
C3S0xxV2
2.5mm
2
AWG 12
C3S1xxV2,
C3S0xxV4, C3S150V4
4.0mm
2
AWG 10
C3S300V4
6.0mm
2
AWG 7