Electromechanical Automation
Product Management & Application
11.02.2008
Klaus Zimmer
Parker Hannifin GmbH & Co KG
EME - Electromechanical Automation Europe
Postfach 17 20 * 77607 Offenburg
Robert-Bosch-Straße 22 * 77656 Offenburg
E-Mail:
C3 I20 T11 ControlManager application note eng.doc
Seite 19 von 20
Version: 16
pic 6
4.5.3 sequence for changing value of stiffness
1. search for necessary Parameters
Name:
Stiffness (control loop dynamics / Stiffness)
C3.ControllerTuning_Stiffness
Object number:
2100.2
Bus format:
U16
unit
%
nPNUIndex
<402>
nPNUSubindex
<2>
2. transfer values via variable table
nPNUIndex
<402>
nPNUSubindex
<2>
the default value for stiffens is 100 % increased by 10 % you get the value „110“:
iParameterValue
<110>
„activate modify values” (see “Variable”).
3. Activate the commandos:
The Bus format is „U16“ a Word Format. So the command for write is „2“ (for
Double Word Format is it „3“).