![Parker Compax3 Series Скачать руководство пользователя страница 57](http://html.mh-extra.com/html/parker/compax3-series/compax3-series_installation-manual_755740057.webp)
Parker EME
Technical Data
192-120102 N7 - February 2004
55
Compax3 Sxxx V4 brake operation
Controller type
S038 V4
S075 V4
S150 V4
S300 V4
Capacitance / storable
energy
235
µ
F / 37Ws 470
µ
F / 75Ws 690
µ
F /
110Ws
1100
µ
F /
176Ws
Minimum ballast -
resistance
100
Ω
56
Ω
22
Ω
15
Ω
Recommended nominal
power rating
60 ... 250W
60 ... 500 W
60 ... 1000 W 60 ... 1000 W
Pulse power rating for 1s
2.5kW
5kW
10 kW
42kW
Ballast resistors for Compax3
Ballast resistor
Device
sustained dynamic
BRM8/01 (100
Ω
Ω
Ω
Ω
)
Compax3 S025 V2
Compax3 S038 V4
60W
250W (<1s;
≥
10s cooling time)
BRM5/01 (56
Ω
Ω
Ω
Ω
)
Compax3 S063 V2
Compax3 S075 V4
180W
2300W (<0.4s;
≥
8s cooling
time)
BRM6/02 (33
Ω
Ω
Ω
Ω
)
Compax3 S150 V4
570W
6900 W (<1s;
≥
20s cooling
time)
BRM4/01 (15
Ω
Ω
Ω
Ω
)
Compax3 S300 V4
570W
6900 W (<1s;
≥
20s cooling
time)
BRM4/02 (15
Ω
Ω
Ω
Ω
)
Compax3 S300 V4
740W
8900W (<1s;
≥
20s cooling time)
BRM4/03 (15
Ω
Ω
Ω
Ω
)
Compax3 S300 V4
1500W
18kW (<1s;
≥
20s cooling time)
Mechanical data
Controller type
Dimensions
HxWxD [mm]
Weight [kg]
Compax3 S025 V2
199 x 84 x 172
2.0
Compax3 S063 V2
199 x 100 x 172
2.5
Compax3 S038 V4
260 x 100 x 172
3.5
Compax3 S075 V4
260 x 115 x 172
4.3
Compax3 S150 V4
260 x 160 x 172
6.8
Compax3 S300 V4
380 x 175 x 172
10.9
Protection type IP20
Safety
Safe standstill as per EN954-1, category
3
!
For implementation of the “protection
against unexpected start-up“ function
described in EN1037.
!
Please note the circuit examples in the
paper manual supplied.
Circuit
examples
(see on page 34).
UL certification
conform to UL:
!
according to UL508C
Certified
!
E-File_No.: E235 342
The UL certification is documented by a UL logo on the
device (type specification plate)
"UL" - logo: