![Parker Compax3 Series Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/parker/compax3-series/compax3-series_installation-manual_755740055.webp)
Parker EME
Technical Data
192-120102 N7 - February 2004
53
For option F12: Direct drives
!
Position resolution per pitch resp. per
revolution (max. 24bit):
!
the analog hall sensors: 13 bits
!
For Sine-Cosine:
13Bit + log
2
(Strokes / Pitch)
!
For TTL (ES422):
2 + log
2
(Strokes / Pitch)
For rotational motors you have to use revolutions
instead of pitch.
!
Accuracy:
The accuracy depends on the
accuracy of the encoders used.
Control voltage 24 VDC
Controller type
Compax3
Voltage range
21 - 27VDC
Current drain of the device
0.8 A
Total current drain
0.8 A + Total load of the digital o
current for the motor holding brake
Ripple
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes
Motors and feedback systems supported
Motors
Direct drives
!
Linear motors
!
Torque motors
!
Sinusoidal commutated synchronous
motors up to maximum rotation speed
of 9000 rpm.
!
3 phase synchronous direct drives
!
Maximum rotating field frequency
600Hz
Position encoder (Feedback)
Option F10: Resolver
Litton:
!
JSSBH-15-E-5
!
JSSBH-21-P4
!
RE-21-1-A05
!
RE-15-1-B04
Tamagawa:
!
2018N321 E64
Siemens:
!
23401-T2509-C202
Option F11: SinCos
©
!
Singleturn (Stegmann)
!
Multiturn (Stegmann) Absolute position
up to 4096 motor revolutions.