GP Outputs 32
−
39
Description
Min
Typical
Max
Units
Turn-on time
--
--
2
ms
Turn-off time
--
--
1
ms
Working voltage
-30
1
--
30
VDC
On-Time voltage drop
(I
L
≤
10 mA)
--
--
0.4
VDC
On-time voltage drop
(10 mA < I
L
≤
100 mA)
--
--
4.0
VDC
Load current (T
A
≤
35 °C)
--
--
100
mA
Load current, I
L
(35 °C < T
A
≤
50 °C)
--
--
80
mA
Short-Circuit trip current
--
200
--
mA
1. The output is not polarity sensitivity, and can be controlled regardless of polarity.
Note
: All parameters are at the connector pin.
Table 26 GP Outputs 32
−
39 Connector Electrical/Timing Characteristics
GP Input/Output Connector Circuit Schematics
This section contains schematics of the input and output circuits of the
ACR9000 and ACR9030 controllers. All inputs have the same circuit
schematic and all outputs have the same circuit schematic.
Figure 15 Equivalent Circuit for GP Inputs/Trigger Inputs Connector
Chapter 2 Specifications 51
www.comoso.com
Содержание ACR9000
Страница 1: ...www comoso com ...
Страница 33: ...Parker Hannifin Figure 7 ACR9040 Front Panel Interfaces Chapter 2 Specifications 33 www comoso com ...
Страница 112: ...Appendix B VM25 Breakout Module A P P E N D I X B VM25 Breakout Module IN THIS CHAPTER Overview 113 www comoso com ...
Страница 114: ...Appendix C VM26 Breakout Module A P P E N D I X C VM26 Breakout Module IN THIS CHAPTER Overview 115 www comoso com ...
Страница 143: ...Appendix F Drive Talk A p p e n d i x F Drive Talk IN THIS CHAPTER Quick Startup 144 www comoso com ...
Страница 159: ...Parker Hannifin Figure 40 ACR9040 Panel Layout Dimensions Appendix G Regulatory Compliance 159 www comoso com ...
Страница 165: ...Parker Hannifin Figure 43 ACR9030 Front Panel Appendix H ETHERNET Powerlink 165 www comoso com ...