General Drive I/O
For problems with the drive function of the Axis I/O, check the following
configurations.
1. If the drive will not enable, verify that the drive’s fault output
configuration is correct (Gemini command,
OUTLVLx1
, etc.). See also
AcroBASIC flag, Enable Drive I/O.
2. If the axis status LED turns red when the drive is disabled, verify that the
drive’s fault output configuration is correct (Aries command,
FLTDSB0
,
etc.).
Note:
Some drives will indicate a drive fault when disabled, and
cause the axis status LED to illuminate red.
Servo Axes
For problems with the servo axes, use the following procedures.
1. If the servo is stable, but the direction of motion is reversed, both the
feedback cabling and commanded Drive AOUT signals are reversed.
Use either:
AcroBASIC remedy (not applicable for SSI feedback devices): Change
the polarity of both the
DAC GAIN
and
MULT
settings.
This reverses both the polarity of the commanded direction and
the feedback direction so that servo stability is maintained.
Hardware remedy: Switch the Drive AOUT+ and Drive AOUT
−
connection to the drive. (If the drive does not support differential
outputs, this will not work.) You must also change the feedback
wiring or mounting so that it counts in the same direction as the
commanded direction. Depending on the feedback device used,
do one of the following:
If your application can change how the feedback device is
mounted, you may be able to affect the count direction with it.
For Quadrature feedback, switch Encoder CHB+ and Encoder
CHB
−
between the controller and the feedback device.
For Step and Direction feedback, switch Encoder CHB+ and
Encoder CHB
−
between the controller and the feedback
device.
For CW and CCW feedback, switch both the CW and CCW signal
pairs between the controller and the feedback device.
For SSI feedback, switch the Drive AOUT+ and Drive AOUT
−
connection between the controller and the drive. (If the drive
does not support differential outputs, switching the connections
will not work.)
Note:
Some SSI encoders may have a polarity
input that can be set to change the count direction.
2. If the servo is unstable, check for the conditions listed below and follow
the recommended steps.
The drive and motor combination are not properly tuned; refer to the
drive installation manual for proper tuning.
Verify that you have attached the axis as a servo and not a stepper.
For more information, see the
ATTACH
command in the ACR
106 ACR9000 Series Hardware Installation Guide
www.comoso.com
Содержание ACR9000
Страница 1: ...www comoso com ...
Страница 33: ...Parker Hannifin Figure 7 ACR9040 Front Panel Interfaces Chapter 2 Specifications 33 www comoso com ...
Страница 112: ...Appendix B VM25 Breakout Module A P P E N D I X B VM25 Breakout Module IN THIS CHAPTER Overview 113 www comoso com ...
Страница 114: ...Appendix C VM26 Breakout Module A P P E N D I X C VM26 Breakout Module IN THIS CHAPTER Overview 115 www comoso com ...
Страница 143: ...Appendix F Drive Talk A p p e n d i x F Drive Talk IN THIS CHAPTER Quick Startup 144 www comoso com ...
Страница 159: ...Parker Hannifin Figure 40 ACR9040 Panel Layout Dimensions Appendix G Regulatory Compliance 159 www comoso com ...
Страница 165: ...Parker Hannifin Figure 43 ACR9030 Front Panel Appendix H ETHERNET Powerlink 165 www comoso com ...