![Parker ACR9000 Скачать руководство пользователя страница 166](http://html1.mh-extra.com/html/parker/acr9000/acr9000_installation-manual_3855262166.webp)
Parker
Hannifin
Figure 44 ACR9040 Front Panel
EPL Ethernet Cable Specification
Use a braid over foil, twisted-pair cable (straight or crossover) for connection
to the Aries EPL drive. An example of this type of cable is L-COM
TRD855SIG-XX. (Although the EPL guidelines call for crossover cables
between EPL devices, the ACR9030, ACR9040, and Aries EPL drive can
autodetect, and as such, either a crossover cable or a straight cable may be
used.)
The maximum cable length is 100m, as defined by Ethernet 100Base-TX
standards.
NOTE:
Due to its lack of noise immunity, unshielded Ethernet cable will not
work in an
ETHERNET
Powerlink system.
166 ACR9000 Series Hardware Installation Guide