![Parker ACR9000 Скачать руководство пользователя страница 100](http://html1.mh-extra.com/html/parker/acr9000/acr9000_installation-manual_3855262100.webp)
Parker
Hannifin
CANopen Connection
Perform the following steps to resolve CANopen network problems.
•
Confirm completion of the installation test on page 90.
•
Verify that each node employs the correct pinout. For the ACR90x0
CANopen connector pinout, see Table 32 on page 58.
•
The ACR90x0 controller provides a network-status LED, which
indicates the state of the CANopen network interface. Use Table 58 on
page 99 to resolve issues indicated by the LED states.
•
CANopen slave nodes typically have a network-status LED; refer to
the device’s documentation for an explanation of the LED states and
resolution of the issues indicated.
Ethernet Connection
Perform the following steps to resolve Ethernet network problems.
1. Verify that you are using the correct type of cable. See Ethernet Cable
2. Verify the cable pin out matches the ACR90x0. See Ethernet Cable
3. The ACR90x0 controller provides a network-status LED, which indicates
the state of the Ethernet connection. See Table 59 on page 99.
Do not proceed until the status LED indicates an Ethernet Link has been
established.
4. Verify a valid IP and subnet mask has been assigned to the ACR90x0.
See Ethernet Cable Specification on page 92.
5. Test the IP and subnet assignment. At a DOS or command prompt type
ping xxx.xxx.xxx.xxx
where xxx.xxx.xxx.xxx represents the IP
address. Compare the response to the following:
a. If you receive a “reply from” message, do the following:
Disconnect the ACR90x0 Ethernet cable and type the
ping
command again.
1. If you see “reply from” message, then another device or
computer has already been assigned the same IP address.
You can change IP address you assigned to the ACR90x0 or
change the IP address of the conflicting device.
2. If you see a “timeout” message, then the ACR90x0 is properly
configured and is network accessible. Re-attach the ACR90x0
Ethernet cable.
b. If a “timeout” message is seen, then the ACR90x0 has an invalid IP
address or subnet mask setting. Determine the correct setting and
update the ACR90x0.
100 ACR9000 Series Hardware Installation Guide
www.comoso.com
Содержание ACR9000
Страница 1: ...www comoso com ...
Страница 33: ...Parker Hannifin Figure 7 ACR9040 Front Panel Interfaces Chapter 2 Specifications 33 www comoso com ...
Страница 112: ...Appendix B VM25 Breakout Module A P P E N D I X B VM25 Breakout Module IN THIS CHAPTER Overview 113 www comoso com ...
Страница 114: ...Appendix C VM26 Breakout Module A P P E N D I X C VM26 Breakout Module IN THIS CHAPTER Overview 115 www comoso com ...
Страница 143: ...Appendix F Drive Talk A p p e n d i x F Drive Talk IN THIS CHAPTER Quick Startup 144 www comoso com ...
Страница 159: ...Parker Hannifin Figure 40 ACR9040 Panel Layout Dimensions Appendix G Regulatory Compliance 159 www comoso com ...
Страница 165: ...Parker Hannifin Figure 43 ACR9030 Front Panel Appendix H ETHERNET Powerlink 165 www comoso com ...