Parker
Hannifin
The next section is specific to the ACR9000 and currently does not
apply to other ACR controllers. The Extended I/O section sets and
clears bits related to homing, hardware and software limits, and
drive faults—all performed behind the scenes and does not come
from user supplied data.
REM ACR Extended IO Settings
SET BIT8468
CLR BIT8464
CLR BIT8470
SET BIT8469
CLR BIT8453
CLR BIT8471
ENC0 SRC 0
ENC0 MULT 4
The next section is specific to the ACR9000 and does not apply to
other ACR controllers. From the Servo Gains dialog, the gain values
are fixed.
REM Axis Gains values
AXIS0 PGAIN 0.002441
AXIS0 IGAIN 0
AXIS0 ILIMIT 0
AXIS0 IDELAY 0
AXIS0 DGAIN 1e-005
AXIS0 DWIDTH 0
AXIS0 FFVEL 0
AXIS0 FFACC 0
AXIS0 TLM 10
AXIS0 FBVEL 0
The next section is specific to the ACR9000 and does not apply to
other ACR controllers. From the Fault dialog, the axis limit features
are enabled and values fixed. Then the DAC gain is fixed, and the
Axis is enabled.
REM Axis Limits
AXIS0 HLDEC 500
SET BIT16144
SET BIT16145
SET BIT16148
SET BIT16149
AXIS0 SLM (24,0)
AXIS0 SLDEC 500
CLR BIT16150
CLR BIT16151
DAC0 GAIN 3276.8
AXIS0 ON
The setup for axes 1 and 2 are similar to axis 0.
ATTACH AXIS1 ENC1 DAC1 ENC1
AXIS1 PPU 39999.999404
AXIS1 EXC (0.2,-0.2)
REM ACR Extended IO Settings
SET BIT8500
CLR BIT8496
CLR BIT8502
SET BIT8501
CLR BIT8485
CLR BIT8503
ENC1 SRC 0
ENC1 MULT 4
REM Axis Gains values
AXIS1 PGAIN 0.002441
AXIS1 IGAIN 0
AXIS1 ILIMIT 0
Basic Setup 43
Содержание ACR Series
Страница 1: ......
Страница 65: ...Parker Hannifin Making Motion 65...
Страница 89: ...Parker Hannifin Servo Loop Fundamentals 89 Figure 17 Following Error...