Parker
Hannifin
Header Code 1
Data Field Data Type
Description
Bit 0
Master Bit 0
Bit 1
Master Bit 1
Bit 2
Master Bit 2
Master for this move packet
Bit 3
Interrupt Select
Interrupt host when move starts
Bit 4
Arc Direction
CCW if set, else CW
Bit 5
Arc Mode
Packet contains center points or
Spline Knot present
Bit 6
Arc Plane Bit 0
Primary and secondary axis or
NURB
Mode
Bit 7
Arc Plane Bit 1
For binary arc move commands or
SPLINE
Mode
Header Code 2
Data Field Data Type
Description
Bit 0
Slave 0 Present
Bit 1
Slave 1 Present
Bit 2
Slave 2 Present
Bit 3
Slave 3 Present
Bit 4
Slave 4 Present
Bit 5
Slave 5 Present
Bit 6
Slave 6 Present
Bit 7
Slave 7 Present
Slave target positions to be contained
in this move packet
Header Code 3
Data Field Data Type
Description
Bit 0
Incremental Target
Target positions are incremental
Bit 1
Incremental Center
Center points are incremental
Bit 2
Floating Point Data
Targets and centers are IEEE32
Bit 3
Arc Radius Scaling
Packet contains radius scaling /
NURB/Spline
Bit 4
FVEL Data Present
Packet contains master
FVEL
Bit 5
Block Skip Check
Sets the master Block Skip Check
Bit 6
NURB or Spline
Move data packet for
NURB
or Spline
Interpolation
Bit 7
Extended Codes
Extended codes 4,5,6 and 7 are
present. This bit should be set if
DBCB is used
Binary Host Interface 115
Содержание ACR Series
Страница 1: ......
Страница 65: ...Parker Hannifin Making Motion 65...