Parameter Reference
D-115
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes MBus
0697
Enable 1 - 32
Parameters::Trips::Trips Status
DWORD
(bitfield)
0000FF7F
5:CURRENT LIMIT
6:MOTOR STALL
7:INVERSE TIME
8:MOTOR I2T
9:LOW SPEED I
11:AMBIENT OVERTEMP
12:MOTOR OVERTEMP
13:EXTERNAL TRIP
14:BRAKE SHORT CCT
15:BRAKE RESISTOR
16:BRAKE SWITCH
17:LOCAL CONTROL
18:COMMS BREAK
19:LINE CONTACTOR
20:PHASE FAIL
21:VDC RIPPLE
22:BASE MODBUS BREAK
23:24V OVERLOAD
24:PMAC SPEED ERROR
25:OVERSPEED
ALWAYS
TECHNICIAN
01921
0703
Enable 1 - 32.CURRENT LIMIT
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01933
0704
Enable 1 - 32.MOTOR STALL
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01935
0705
Enable 1 - 32.INVERSE TIME
Parameters::Trips::Trips Status
BOOL
FALSE
ALWAYS
TECHNICIAN
01937
0706
Enable 1 - 32.MOTOR I2T
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01939
0707
Enable 1 - 32.LOW SPEED I
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01941
0709
Enable 1 - 32.AMBIENT OVERTEMP
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01945
0710
Enable 1 - 32.MOTOR OVERTEMP
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01947
0711
Enable 1 - 32.EXTERNAL TRIP
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01949
0712
Enable 1 - 32.BRAKE SHORT CCT
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01951
0713
Enable 1 - 32.BRAKE RESISTOR
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01953
0714
Enable 1 - 32.BRAKE SWITCH
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01955
0715
Enable 1 - 32.LOCAL CONTROL
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01957
0716
Enable 1 - 32.COMMS BREAK
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01959
0717
Enable 1 - 32.LINE CONTACTOR
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01961
0718
Enable 1 - 32.PHASE FAIL
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01963
0719
Enable 1 - 32.VDC RIPPLE
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01965
0720
Enable 1 - 32.BASE MODBUS BREAK
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01967
0721
Enable 1 - 32.24V OVERLOAD
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01969
0722
Enable 1 - 32.PMAC SPEED ERROR
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01971
0723
Enable 1 - 32.OVERSPEED
Parameters::Trips::Trips Status
BOOL
TRUE
ALWAYS
TECHNICIAN
01973
Содержание AC30V Series
Страница 33: ...4 15 Installation AC30V series Variable Speed Drive Wiring Diagrams APPLICATION 0 BASIC SPEED CONTROL...
Страница 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Страница 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Страница 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Страница 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Страница 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Страница 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Страница 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Страница 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Страница 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Страница 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Страница 174: ...Compliance C 8 AC30V series Variable Speed Drive Conducted Emissions Profile Unfiltered Product Frame D Frame E Frame F...
Страница 277: ...D 80 Parameter Reference AC30V series Variable Speed Drive Setpoint Drive Frequency Frequency 1 Frequency 2...
Страница 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...