![Parker AC30 series Скачать руководство пользователя страница 485](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313485.webp)
Parameter Reference
D-225
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
1918 Preset Speed 2
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS TECHNICIAN 5,8
04363
1919 Preset Speed 3
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS TECHNICIAN 5,8
04365
1920 Preset Speed 4
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS TECHNICIAN 5,8
04367
1921 Preset Speed 5
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS TECHNICIAN 5,8
04369
1922 Preset Speed 6
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS TECHNICIAN 5,8
04371
1923 Preset Speed 7
Setup::Application::Preset Speeds
REAL
0.0
-100.0 to 100.0
%
ALWAYS TECHNICIAN 5,8
04373
1924 Selected Preset
Monitor::Application::Preset Speeds
USINT
0 to 7
NEVER
TECHNICIAN 8
04375
1925 Preset Speed Output
Monitor::Application::Preset Speeds
REAL
-100.0 to 100.0
%
NEVER
TECHNICIAN 8
04377
1926 PID Setpoint Negate
Setup::Application::PID
BOOL
TRUE
ALWAYS TECHNICIAN 5,8
04379
1927 PID Feedback Negate
Setup::Application::PID
BOOL
TRUE
ALWAYS TECHNICIAN 5,8
04381
1928 PID Proportional Gain
Setup::Application::PID
REAL
1.0
ALWAYS TECHNICIAN 5,8
04383
1929 PID Integral TC
Setup::Application::PID
TIME
1.00
0.01 to 100.00
s
ALWAYS TECHNICIAN 5,8
04385
1930 PID Derivative TC
Setup::Application::PID
TIME
0.000
0.000 to 10.000
s
ALWAYS TECHNICIAN 5,8
04387
1931 PID Output Filter TC
Setup::Application::PID
TIME
0.100
0.000 to 10.000
s
ALWAYS TECHNICIAN 5,8
04389
1932 PID Output Pos Limit
Setup::Application::PID
REAL
100.00
0.00 to 105.00
%
ALWAYS TECHNICIAN 5,8
04391
1933 PID Output Neg Limit
Setup::Application::PID
REAL
-100.00
-105.00 to 0.00
%
ALWAYS TECHNICIAN 5,8
04393
1934 PID Output Scaling
Setup::Application::PID
REAL
1.000
-10.000 to 10.000
ALWAYS TECHNICIAN 5,8
04395
1935 PID Output
Monitor::Application::PID
REAL
-105.00 to 105.00
%
NEVER
TECHNICIAN 8
04397
1936 PID Error
Monitor::Application::PID
REAL
-105.00 to 105.00
%
NEVER
TECHNICIAN 8
04399
1937 Disable Coast Stop
Setup::Application::Sequencing
BOOL
TRUE
ALWAYS TECHNICIAN 8
04401
1938 Disable Quickstop
Setup::Application::Sequencing
BOOL
TRUE
ALWAYS TECHNICIAN 8
04403
1939 Feedback On ANIN1
Setup::Application::Input Selection
BOOL
FALSE
ALWAYS TECHNICIAN 8
04405
Содержание AC30 series
Страница 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Страница 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Страница 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Страница 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Страница 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Страница 58: ...4 37 Installation AC30 series Variable Speed Inverter AFE Control Wiring Excludes 7004 04 00 Wiring...
Страница 149: ...Setup Wizard 9 24 AC30 series Variable Speed Inverter MONITOR THE DRIVE Figure 9 15 Monitor the Drive and fine tune...
Страница 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Страница 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Страница 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Страница 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Страница 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Страница 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...