![Parker AC30 series Скачать руководство пользователя страница 477](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313477.webp)
Parameter Reference
D-217
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
1181 Anin 11 Value
Monitor::Inputs and Outputs
Parameters::Option IO::General Purpose IO
REAL
x.xx
-100.00 to 100.00
%
NEVER
OPERATOR
02889
1182 Anin 12 Value
Same as PNO 1181
REAL
x.xx
-100.00 to 100.00
%
NEVER
OPERATOR
02891
1183 Anin 13 Value
Same as PNO 1181
REAL
x.xx
-100.00 to 100.00
%
NEVER
OPERATOR
02893
1184 Thermistor Type
Setup::Inputs and Outputs::Option
Parameters::Option IO::Thermistor
USINT
(enum)
1
0:NTC
1:PTC
2:KTY
ALWAYS TECHNICIAN
02895
1185 Thermistor Resistance
Parameters::Option IO::Thermistor
REAL
x.
0 to 5000
Ohm
NEVER
TECHNICIAN
02897
1186 Time and Date
Parameters::Device Manager::Real Time Clock
DT
1970/01/01
1970/01/01 to 2106/02/07
ALWAYS OPERATOR
2
02899
1187 RTC Trim
Parameters::Option IO::General Purpose IO
SINT
0
-40 to 40
ALWAYS ENGINEER
2
02901
1188 Favourites
Parameters::Device Manager::Soft Menus
ARRAY[0..19]
ALWAYS OPERATOR
02903
1189 Favourites[0]
Favourites
Parameters::Device Manager::Soft Menus
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02905
1190 Favourites[1]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02907
1191 Favourites[2]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02909
1192 Favourites[3]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02911
1193 Favourites[4]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02913
1194 Favourites[5]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02915
1195 Favourites[6]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02917
1196 Favourites[7]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02919
1197 Favourites[8]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02921
1198 Favourites[9]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02923
1199 Favourites[10]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02925
1200 Favourites[11]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02927
1201 Favourites[12]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02929
1202 Favourites[13]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02931
1203 Favourites[14]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02933
1204 Favourites[15]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02935
1205 Favourites[16]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02937
1206 Favourites[17]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02939
1207 Favourites[18]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02941
1208 Favourites[19]
Same as PNO 1189
UINT
0000
0000 to 2149
ALWAYS OPERATOR
02943
1239 Local Run Key Active
Parameters::Keypad::Local Control
BOOL
TRUE
ALWAYS TECHNICIAN
03005
1240 Local Reverse
Parameters::Keypad::Local Control
BOOL
FALSE
ALWAYS OPERATOR
1
03007
1241 Open Connections
Monitor::Communications::Base Modbus
Parameters::Base Comms::Modbus
USINT
0 to 255
NEVER
OPERATOR
03009
1246 Speed Loop Auto Set
Parameters::Motor Control::Spd Loop Settings
BOOL
TRUE
ALWAYS TECHNICIAN
03019
1247 Ratio Load Mot Inert
Parameters::Motor Control::Spd Loop Settings
REAL
1.0
0.1 to 100.0
ALWAYS TECHNICIAN
03021
1248 Speed Loop Bandwidth
Parameters::Motor Control::Spd Loop Settings
USINT
(enum)
1
0:LOW
1:MEDIUM
2:HIGH
ALWAYS TECHNICIAN
03023
1251 CANopen Actual Baud
Monitor::Communications::Option
Parameters::Option Comms::CANopen
USINT
(enum)
Same as PNO 213
NEVER
OPERATOR
03029
1252 HV SMPS Up Time
Parameters::Device Manager::Runtime Statistics
UDINT
0 to Max
s
NEVER
TECHNICIAN 1
03031
1253 Local/Rem Key Active
Parameters::Keypad::Local Control
BOOL
TRUE
ALWAYS TECHNICIAN
03033
1254 IO Option SW Version
Parameters::Device Manager::Drive info
WORD
NEVER
OPERATOR
03035
1255 Local Dir Key Active
Parameters::Keypad::Local Control
BOOL
TRUE
ALWAYS TECHNICIAN
03037
1256 OEM ID
Parameters::Device Manager::Drive info
UINT
0 to 65535
NEVER
ENGINEER
03039
1257 Seq Stop Method SVC
Setup::Motor Control::Control and Type
Parameters::Motor Control::Ramp
USINT
(enum)
1
0:DISABLED VOLTAGE
1:RAMP
2:STOP RAMP
ALWAYS TECHNICIAN
03041
1258 Stack Serial No
Parameters::Device Manager::Drive info
STRING[15]
NEVER
OPERATOR
03043
1264 Ref Min Speed Clamp
Parameters::Motor Control::Speed Ref
REAL
-110.00
-110.00 to 0.00
%
ALWAYS OPERATOR
03055
1265 Ref Max Speed Clamp
Parameters::Motor Control::Speed Ref
REAL
110.00
0.00 to 110.00
%
ALWAYS OPERATOR
03057
1266 Ref Speed Trim
Parameters::Motor Control::Speed Ref
REAL
0.00
-300.00 to 300.00
%
ALWAYS OPERATOR
03059
1267 Ref Trim Local
Parameters::Motor Control::Speed Ref
BOOL
FALSE
ALWAYS OPERATOR
03061
1268 Random Pattern PMAC
Parameters::Motor Control::Pattern Generator
BOOL
FALSE
ALWAYS ENGINEER
03063
1269 DHCP State
Parameters::Base Comms::Ethernet
DWORD
NEVER
ENGINEER
03065
1270 Monitor
Parameters::Device Manager::Soft Menus
ARRAY[0..19]
ALWAYS OPERATOR
03067
1271 Monitor[0]
Monitor::Quick Monitor
Parameters::Device Manager::Soft Menus
UINT
0383
0000 to 2149
ALWAYS OPERATOR
2
03069
1272 Monitor[1]
Same as PNO 1271
UINT
0393
0000 to 2149
ALWAYS OPERATOR
2
03071
1273 Monitor[2]
Same as PNO 1271
UINT
0395
0000 to 2149
ALWAYS OPERATOR
2
03073
1274 Monitor[3]
Same as PNO 1271
UINT
0696
0000 to 2149
ALWAYS OPERATOR
2
03075
1275 Monitor[4]
Same as PNO 1271
UINT
0895
0000 to 2149
ALWAYS OPERATOR
2
03077
1276 Monitor[5]
Same as PNO 1271
UINT
0926
0000 to 2149
ALWAYS OPERATOR
2
03079
Содержание AC30 series
Страница 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Страница 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Страница 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Страница 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Страница 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Страница 58: ...4 37 Installation AC30 series Variable Speed Inverter AFE Control Wiring Excludes 7004 04 00 Wiring...
Страница 149: ...Setup Wizard 9 24 AC30 series Variable Speed Inverter MONITOR THE DRIVE Figure 9 15 Monitor the Drive and fine tune...
Страница 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Страница 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Страница 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Страница 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Страница 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Страница 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...