![Parker AC30 series Скачать руководство пользователя страница 251](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313251.webp)
Compliance
C-38
AC30 series Variable Speed Inverter
CANADIAN COMPLIANCE
Only AC fed products have been approved by Intertek Testing and Certification Ltd (ETL) to Canadian Standard CSA 22.2 No. 14, Standard for
Industrial Control Equipment and Canadian Standard CSA 22.2 No. 14, Industrial control Equipment.
NORTH AMERICAN AND CANADIAN COMPLIANCE INFORMATION
Motor Base Frequency
PMAC and Induction motor modes are identical.
Drive Switching Frequency Maximum Output Frequency
4 kHz
500Hz
8 kHz
590Hz (1000Hz subject EU Export Control Annex I to Council Regulation (EC) No. 428/2009)
12 kHz
590Hz (1500Hz subject EU Export Control Annex I to Council Regulation (EC) No. 428/2009)
16 kHz
590Hz (1500Hz subject EU Export Control Annex I to Council Regulation (EC) No. 428/2009)
Drive Protection
Branch Circuit Protection
It is recommended that UL Listed non-renewable cartridge fuses (JDDZ) or UL Listed renewable cartridge fuses (JDRX) are installed upstream of
the drive. Refer to Appendix F: “Technical Specifications” - Power Details for recommended fuse ratings.
Solid-State Motor Overload Protection
This product provides Class 10 motor overload protection. The maximum internal overload protection level (current limit) is 180% for 3 seconds,
in addition Heavy Duty mode is 150% for 60 seconds and Normal Duty mode is 110% for 60s in. Refer to Appendix D Programming –
Current
Limit
for user current limit adjustment information.
An external motor overload protective device must be provided by the installer where the motor has a full-load Ampere rating of less than 50% of
the drive output rating or when the
Disable Stall
trip is enabled; or when the
Stall time
parameter is increased above 480 seconds (refer to
Appendix D Programming :
Stall Trip
).
Motor over temperature sensing is not provided by the product unless the external temperature sensor is connected to the motor thermistor input
on the GPIO option. When the GPIO option is not fitted an external motor over temperature device is required.
Содержание AC30 series
Страница 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Страница 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Страница 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Страница 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Страница 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Страница 58: ...4 37 Installation AC30 series Variable Speed Inverter AFE Control Wiring Excludes 7004 04 00 Wiring...
Страница 149: ...Setup Wizard 9 24 AC30 series Variable Speed Inverter MONITOR THE DRIVE Figure 9 15 Monitor the Drive and fine tune...
Страница 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Страница 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Страница 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Страница 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Страница 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Страница 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...