![Parker AC30 series Скачать руководство пользователя страница 482](http://html2.mh-extra.com/html/parker/ac30-series/ac30-series_user-manual_3745313482.webp)
D-222
Parameter Reference
AC30 series Variable Speed Drive
PNO Name
Path
Type
Default
Range
Units
WQ
View
Notes MBus
1633 Application User Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.00
0.00 to 25.00
%
ALWAYS OPERATOR
03793
1634 Start Delay
Parameters::Motor Control::Motor Sequencer
TIME
0.000
0.000 to 30.000
s
STOPPED TECHNICIAN
03795
1635 Delay To Start
Parameters::Motor Control::Motor Sequencer
TIME
0.000 to Max
s
NEVER
TECHNICIAN
03797
1636 Manufacturing Flags
Parameters::Device Manager::Drive info
WORD
NEVER
ENGINEER
03799
1637 Engineer Password
Parameters::Keypad::Graphical Keypad
WORD
0000
ALWAYS TECHNICIAN
03801
1640 Modbus Password
Setup::Communications::Option
Parameters::Option Comms::Modbus RTU
WORD
0000
ALWAYS TECHNICIAN
03807
1641 VDC Lim Enable
Parameters::Motor Control::DC Link Volts Limit
BOOL
FALSE
STOPPED TECHNICIAN
03809
1642 VDC Lim Level
Parameters::Motor Control::DC Link Volts Limit
REAL
91.0
78.0 to 100.0
%
STOPPED TECHNICIAN
03811
1643 VDC Lim Active
Parameters::Motor Control::DC Link Volts Limit
BOOL
NEVER
TECHNICIAN
03813
1644 VDC Lim Output
Parameters::Motor Control::DC Link Volts Limit
REAL
x.x
Min to Max
Hz
NEVER
ENGINEER
03815
1645 Pwrl Enable
Parameters::Motor Control::Power Loss Ride Thru BOOL
FALSE
STOPPED TECHNICIAN
03817
1646 Pwrl Trip Threshold
Parameters::Motor Control::Power Loss Ride Thru REAL
52.0
20.0 to 60.0
%
STOPPED TECHNICIAN
03819
1647 Pwrl Control Band
Parameters::Motor Control::Power Loss Ride Thru REAL
2.0
0.0 to 20.0
%
STOPPED TECHNICIAN
03821
1648 Pwrl Accel Rate
Parameters::Motor Control::Power Loss Ride Thru REAL
100
1 to 500
Hz/s
STOPPED TECHNICIAN
03823
1649 Pwrl Decel Rate
Parameters::Motor Control::Power Loss Ride Thru REAL
100
1 to 500
Hz/s
STOPPED TECHNICIAN
03825
1650 Pwrl Time Limit
Parameters::Motor Control::Power Loss Ride Thru TIME
30.000
0.000 to 300.000
s
STOPPED TECHNICIAN
03827
1651 Pwrl Active
Parameters::Motor Control::Power Loss Ride Thru BOOL
NEVER
TECHNICIAN
03829
1658 Current Diff Level
Parameters::Trips::Current Sensor Trip
REAL
25.00
0.00 to 100.00
%
ALWAYS OPERATOR
03843
1659 Modbus TCP Password
Setup::Communications::Base Modbus
Parameters::Base Comms::Modbus
WORD
0000
ALWAYS TECHNICIAN
03845
1661 PTP Enable
Setup::Communications::PTP
Parameters::Base Comms::PTP
BOOL
FALSE
ALWAYS TECHNICIAN
03849
1663 Encoder Supply
Setup::Inputs and Outputs::SB Encoder Slot1
Parameters::System Board::Encoder Slot 1
USINT
(enum)
0
0:5 V
1:12 V
2:15 V
3:20 V
STOPPED TECHNICIAN
03853
1664 Encoder Lines
Same as PNO 1663
DINT
2048
1 to 100000
STOPPED TECHNICIAN
03855
1665 Encoder Invert
Same as PNO 1663
BOOL
FALSE
STOPPED TECHNICIAN
03857
1666 Encoder Type
Same as PNO 1663
USINT
(enum)
0
Same as PNO 1514
STOPPED TECHNICIAN
03859
1667 High Input Threshold
Same as PNO 1663
BOOL
FALSE
STOPPED TECHNICIAN
03861
1668 Encoder Speed
Parameters::System Board::Encoder Slot 1
REAL
x.
Min to Max
RPM
NEVER
TECHNICIAN
03863
1669 Encoder Count Reset
Same as PNO 1663
BOOL
FALSE
ALWAYS TECHNICIAN 2
03865
1670 Encoder Count
Parameters::System Board::Encoder Slot 1
DINT
-214783648 to 214783647
NEVER
TECHNICIAN
03867
1671 Encoder Lines
Parameters::System Board::Encoder Slot 2
DINT
2048
1 to 100000
STOPPED TECHNICIAN
03869
1672 Encoder Invert
Parameters::System Board::Encoder Slot 2
BOOL
FALSE
STOPPED TECHNICIAN
03871
1673 Encoder Type
Parameters::System Board::Encoder Slot 2
USINT
(enum)
0
Same as PNO 1514
STOPPED TECHNICIAN
03873
1674 High Input Threshold
Parameters::System Board::Encoder Slot 2
BOOL
FALSE
STOPPED TECHNICIAN
03875
1675 Encoder Speed
Parameters::System Board::Encoder Slot 2
REAL
x.
Min to Max
RPM
NEVER
OPERATOR
03877
1676 Encoder Count Reset
Parameters::System Board::Encoder Slot 2
BOOL
FALSE
ALWAYS TECHNICIAN 2
03879
1677 Encoder Count
Parameters::System Board::Encoder Slot 2
DINT
-214783648 to 214783647
NEVER
TECHNICIAN
03881
1678 Output Enable
Setup::Inputs and Outputs::System Board Option
Parameters::System Board::System Board IO
BOOL
FALSE
ALWAYS ENGINEER
03883
1679 Output Source
Same as PNO 1678
USINT
(enum)
0
0:SYSTEM BOARD SLOT 1
1:SYSTEM BOARD SLOT 2
2:SYNTHETIC ENCDR
3:DIGITAL OUTPUTS
STOPPED ENGINEER
03885
1680 Output Voltage
Same as PNO 1678
USINT
(enum)
0
Same as PNO 1663
ALWAYS ENGINEER
03887
1681 PTP Log Sync Interval
Same as PNO 1661
SINT
-1
-1 to 0
ALWAYS ENGINEER
03889
1682 Random Pattern AFE
Parameters::Motor Control::Pattern Generator
BOOL
FALSE
ALWAYS ENGINEER
03891
1683 PTP Clock Mode
Same as PNO 1661
USINT
(enum)
0
0:E2E
ALWAYS ENGINEER
03893
1684 PTP Clock Type
Same as PNO 1661
USINT
(enum)
0
0:MASTER OR SLAVE
1:SLAVE ONLY
ALWAYS ENGINEER
03895
1685 PTP Lock Threshold
Same as PNO 1661
REAL
0.5
0.1 to 100.0
us
ALWAYS ENGINEER
03897
1686 PTP Priority2
Same as PNO 1661
USINT
128
0 to 255
ALWAYS ENGINEER
03899
1687 PTP Offset
Monitor::Communications::PTP
Parameters::Base Comms::PTP
DINT
Min to Max
ns
NEVER
OPERATOR
03901
1688 PTP Locked
Same as PNO 1687
BOOL
NEVER
OPERATOR
03903
1689 PTP State
Same as PNO 1687
USINT
(enum)
0:NONE
1:INITIALISNG
2:FAULTY
NEVER
OPERATOR
03905
Содержание AC30 series
Страница 48: ...4 27 Installation AC30 series Variable Speed Inverter Basic Speed Control Wiring...
Страница 50: ...4 29 Installation AC30 series Variable Speed Inverter Auto Manual Control Wiring...
Страница 52: ...4 31 Installation AC30 series Variable Speed Inverter Raise Lower Trim Wiring...
Страница 54: ...4 33 Installation AC30 series Variable Speed Inverter Presets Speeds Wiring...
Страница 56: ...4 35 Installation AC30 series Variable Speed Inverter PID Control Wiring...
Страница 58: ...4 37 Installation AC30 series Variable Speed Inverter AFE Control Wiring Excludes 7004 04 00 Wiring...
Страница 149: ...Setup Wizard 9 24 AC30 series Variable Speed Inverter MONITOR THE DRIVE Figure 9 15 Monitor the Drive and fine tune...
Страница 150: ...9 25 Setup Wizard AC30 series Variable Speed Inverter Figure 9 16 Charting Drive Parameters...
Страница 233: ...Compliance C 20 AC30 series Variable Speed Inverter Frame H...
Страница 234: ...C 21 Compliance AC30 series Variable Speed Inverter Frame J...
Страница 266: ...D 6 Parameter Reference AC30 series Variable Speed Drive...
Страница 343: ...Parameter Reference D 83 AC30 series Variable Speed Drive Offset Input 100 100 x Scale Value...
Страница 495: ...E Plan Library E 2 AC30 series Variable Speed Inverter Which then brings up the E Plan page...