background image

Refrigerating Specialties Division

1

ISO 9001:2000 CERTIFIED

ADAPTOMODE WELD-END
PRESSURE REGULATORS

Types:  A4W, A4WE, A4WS, A4WB,

 

A4WD, A4WP, A4WOE, A4WR

Port Size 125-200mm (5”-8”)
FOR AMMONIA, R12, R22, R502 
AND OTHER COMMON REFRIGERANTS

FEATURES

•  Cast Steel Body – Strong, Lightweight.

•  Welds Directly in the Line – No Flanges.

•  Removable Seat – Serviceable from Top Side.

•  Streamlined Fluid Flow Pattern.

•  Unique Modular Construction – Same Modules 

as A4A Series.

•  Interchangeable Parts.

•  Easy to Service.

•  Pilot Operated Characterized Modulating Plug for 

Precise Control.

•  Suitable for All Common Refrigerants and Oil.

•  27.6 bar (400 psig) Maximum Rated Pressure (MRP).

•  Many Control Variations are Possible with the Use 

of a Few Modules and Kits.

•  Stainless Steel Diaphragm.

•  Chrome Plated Pilot Seat.

•  Manual Opening Stem.

Index

   Item  ...................................................................................... Page
   A4W  .............................................................................................1
   A4WB  ...........................................................................................3
   A4WD ............................................................................................4
   A4WE ........................................................................................... 2
   A4WOE ...................................................................................... 2, 4
   A4WP ............................................................................................4
   A4WR ............................................................................................5
   A4WS ............................................................................................3
   Adjustment, Range  ......................................................................2
   Assembly ......................................................................................6
   Dimension Drawings ............................................................ 12, 13
   Disassembly .................................................................................6
   Electrical ......................................................................................5
   Installation ...................................................................................5
   Mintenance and Service ...............................................................8
   Manual Opening Stem  ............................................................  8, 9
   Pressure Setting Ranges .............................................................2
   Safe Operation  ..........................................................................  14
   Torques, Fastener and Seat  ........................................................7
   Trouble Shooting  ........................................................................ 9
   Warning  .....................................................................................14
   Warranty .....................................................................................14

BULLETIN 23-20D

A4W Series

August 2007

Installation, Service and Parts Information

Description

These heavy duty, cast steel bodied (ASTIM No. A352 Grade 
LCB), pressure regulators weld directly in the line and do not 
require fl anges.

They are used for control of Ammonia, R-12, R-22 and R-502, 
and other common refrigerants, certain oils and other fl uids 
approved for use in refrigeration systems.

The A4W Series Regulators are pilot operated, using upstream 
pressure for the moving force, and require a minimum 0.14 bar 
(2 psi) pressure drop to fully open. The basic Type A4W is an Inlet 
Pressure Regulator which tends to open on a rise in upstream 
pressure above set-point and to close on a drop in pressure 
below set-point.

These valves can be ordered with the Type RSW Strainer to be 
welded directly to the inlet of any of the Type A4W Regulators 
or use a 13mm (1/2”) Type RSF Strainer in only the pilot circuit 
of a Type A4WE or A4WR version of the regulator.

The A4W Series of regulators uses the same Modules as does 
the A4A Series to confi gure many possible variations.

Seal Cap

Manual 
Opening 
Stem

Power 
Piston

Removable Seat

Seal Cap

Adjusting Stem

Range Spring

Diaphragm

Gauge Port

Pilot Seat

Modulating 
Plug

Closing 
Spring

Fig. 1 - A4W, A4WE

050405

Содержание A4W Series

Страница 1: ...rouble Shooting 9 Warning 14 Warranty 14 BULLETIN 23 20D A4W Series August 2007 Installation Service and Parts Information Description These heavy duty cast steel bodied ASTIM No A352 Grade LCB pressu...

Страница 2: ...gauge port Back the Adjusting Stem all of the way out to stop counterclockwise This will reduce the set point to its lowest level and will cause the valve to OPEN wide Start the system and when the va...

Страница 3: ...frequently is used in the wide open mode when maximum refrigeration capacity from an evaporator is required During the defrost of the evaporator the regulator pilot solenoid is de energized thus funct...

Страница 4: ...imum system performance To adjust the pressure regulator disconnect the air line and follow the instructions above listed for the Type A4W This setting represents the lowest inlet pressure the regulat...

Страница 5: ...gauge installed on the regulator can be seen Avoid locations where the valve may be damaged by personnel traf c material handling or other equipment Before installing the valve check to see that all...

Страница 6: ...l bar approximately 10mm x 50mm 3 8 x 2 x 50 2 longer than the diameter of the piston bore Drill a hole in the center of the at face that will clear the 1 4 20 screw Obtain a 1 4 20 machine screw with...

Страница 7: ...talled bowed toward the Diaphragm Follower 47 and Range Spring 49 That is the center of the Diaphragm is higher than its perimeter Before installing the Bonnet 51 be sure that the Adjusting Stem 52 is...

Страница 8: ...rbon systems Before deciding to disassemble a regulator for servicing the following investigations should be made Check the Manual Opening Stem it should be turned out counterclockwise for automatic o...

Страница 9: ...in parallel Check with factory Pressure drop across Inlet or outlet restricted Check for restriction regulator too high Clean strainer Regulator too small Replace with properly sized regulator High pr...

Страница 10: ...Pilot Range V Not A4WOE 202004 44 Seat Pilot 1 Diaphragm Kit 200770 1 Seat Kit Pilot Range D Not A4WOE 202003 44 Seat Pilot 1 Diaphragm Kit 200771 1 Bolt Package A4W Bonnet 202246 58 Bolts 5 16 18 x...

Страница 11: ...Refrigerating Specialties Division 11 Fig 8 Fig 9 S6A Pilot...

Страница 12: ...Refrigerating Specialties Division 12 Fig 12 A4W A4WE A4WP A4WL A4WOE A4WR A4WB A4WS For All Sizes e is 75mm 3 0 in f is 100mm 4 0 in g is 140mm 5 5 in A4WD...

Страница 13: ...17 25 A4WP A4WL mm 438 318 In 17 25 12 5 A4WOE mm 463 305 In 18 25 12 0 A4WR mm 414 305 In 16 25 12 0 A4WB A4WS mm 476 451 In 18 75 17 75 A4WD mm 502 476 In 19 75 18 75 mm 150 Common to All mm 152 48...

Страница 14: ...ervicing work Where cold refrigerant liquid lines are used it is necessary that certain precautions be taken to avoid damage which could result from liquid expansion Temperature increase in a piping s...

Отзывы: