Warranty

All Refrigerating Specialties Products are warranted against 
defect in workmanship and materials for a period of one year 
from date of shipment from factory. This warranty is in force 
only when products are properly installed, fi eld assembled, 
maintained and operated in use and service as specifi cally 
stated in Refrigerating Specialties Catalogs or Bulletins for 
normal refrigeration applications, unless otherwise approved 
in writing by Refrigerating Specialties Division. Defective 
products, or parts thereof, returned to the factory with 
transportation charges prepaid and found to be defective by 
factory inspection will be replaced or repaired at Re frigerating 
Specialties’ option, free of charge, F.O.B. factory. Warranty does 
not cover products which have been altered or repaired in the 
fi eld; damaged in transit, or have suffered accidents, misuse, 
or abuse. Prod ucts disabled by dirt or other foreign substances 
will not be considered defective.

THE EXPRESS WARRANTY SET FORTH ABOVE CONSTITUTES 
THE ONLY WARRANTY APPLICABLE TO REFRIGERATING 
SPECIALTIES PRODUCTS, AND IS IN LIEU OF ALL OTHER 
WARRANTIES, EX PRESS OR IMPLIED, WRITTEN OR ORAL, 
INCLUDING ANY WAR RANTY OF MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, 
dealer or other person is authorized to give any warranties 
on behalf of Refrigerating Specialties, nor to assume, for 
Refrigerating Specialties, any other liability in connection with 
any of its products.

Safe Operation (See also Bulletin RSBCV)

People doing any work on a refrigeration system must be 
qualifi ed and completely familiar with the system and the 
Refrigerating Specialties Division Products involved, or all 
other precautions will be meaningless. This includes reading 
and understanding pertinent Refrigerating Special ties Division 
Product Bulletins, and Safety Bulletin RSB prior to installa tion 
or servicing work.

Where cold refrigerant liquid lines are used, it is necessary 
that certain precautions be taken to avoid damage which could 
result from liquid expansion. Temperature increase in a piping 
section full of solid liquid will cause high pressure due to the 
expanding liquid which can possibly rupture a gasket, pipe 
or valve. All hand valves isolating such sections should be 
marked, warning against accidental closing, and must not be 
closed until the liquid is removed. Check valves must never be 
installed upstream of solenoid valves, or regulators with electric 
shut-off, nor should hand valves upstream of solenoid valves or 
downstream of check valves be closed until the liquid has been 
removed. It is advisable to properly install relief devices in any 
section where liquid expansion could take place.

Avoid all piping or control arrangements which might produce 
thermal or pressure shock.

For the protection of people and products, all refrigerant must 
be removed from the section to be worked on before a valve, 
strainer, or other device is opened or removed.

Flanges with ODS connections are not suitable for ammonia 
service.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF 
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR 
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND 
PROPERTY DAMAGE.

This document and other information from Parker Hannifi n 
Corporation, its subsidiaries and authorized distributors 
provide product and/or system options for further investigation 
by users having technical expertise.  It is important that 
you analyze all aspects of your application and review 
the information concerning the product or system in the

current product catalog.  Due to the variety of operating 
conditions and applications for these products or systems, 
the user through its own analysis and testing, is solely 
responsible for making the fi nal selection of the products and 
systems and assuring that all performance, safety and warning 
requirements of the application are met.

The products described herein, including without limitation, 
product features, specifications, designs, availability and 
pricing, are subject to change by Parker Hannifi n Corporation 
and its subsidiaries at any time without notice.

Содержание A4W Series

Страница 1: ...rouble Shooting 9 Warning 14 Warranty 14 BULLETIN 23 20D A4W Series August 2007 Installation Service and Parts Information Description These heavy duty cast steel bodied ASTIM No A352 Grade LCB pressu...

Страница 2: ...gauge port Back the Adjusting Stem all of the way out to stop counterclockwise This will reduce the set point to its lowest level and will cause the valve to OPEN wide Start the system and when the va...

Страница 3: ...frequently is used in the wide open mode when maximum refrigeration capacity from an evaporator is required During the defrost of the evaporator the regulator pilot solenoid is de energized thus funct...

Страница 4: ...imum system performance To adjust the pressure regulator disconnect the air line and follow the instructions above listed for the Type A4W This setting represents the lowest inlet pressure the regulat...

Страница 5: ...gauge installed on the regulator can be seen Avoid locations where the valve may be damaged by personnel traf c material handling or other equipment Before installing the valve check to see that all...

Страница 6: ...l bar approximately 10mm x 50mm 3 8 x 2 x 50 2 longer than the diameter of the piston bore Drill a hole in the center of the at face that will clear the 1 4 20 screw Obtain a 1 4 20 machine screw with...

Страница 7: ...talled bowed toward the Diaphragm Follower 47 and Range Spring 49 That is the center of the Diaphragm is higher than its perimeter Before installing the Bonnet 51 be sure that the Adjusting Stem 52 is...

Страница 8: ...rbon systems Before deciding to disassemble a regulator for servicing the following investigations should be made Check the Manual Opening Stem it should be turned out counterclockwise for automatic o...

Страница 9: ...in parallel Check with factory Pressure drop across Inlet or outlet restricted Check for restriction regulator too high Clean strainer Regulator too small Replace with properly sized regulator High pr...

Страница 10: ...Pilot Range V Not A4WOE 202004 44 Seat Pilot 1 Diaphragm Kit 200770 1 Seat Kit Pilot Range D Not A4WOE 202003 44 Seat Pilot 1 Diaphragm Kit 200771 1 Bolt Package A4W Bonnet 202246 58 Bolts 5 16 18 x...

Страница 11: ...Refrigerating Specialties Division 11 Fig 8 Fig 9 S6A Pilot...

Страница 12: ...Refrigerating Specialties Division 12 Fig 12 A4W A4WE A4WP A4WL A4WOE A4WR A4WB A4WS For All Sizes e is 75mm 3 0 in f is 100mm 4 0 in g is 140mm 5 5 in A4WD...

Страница 13: ...17 25 A4WP A4WL mm 438 318 In 17 25 12 5 A4WOE mm 463 305 In 18 25 12 0 A4WR mm 414 305 In 16 25 12 0 A4WB A4WS mm 476 451 In 18 75 17 75 A4WD mm 502 476 In 19 75 18 75 mm 150 Common to All mm 152 48...

Страница 14: ...ervicing work Where cold refrigerant liquid lines are used it is necessary that certain precautions be taken to avoid damage which could result from liquid expansion Temperature increase in a piping s...

Отзывы: