Adjustment Guide: 

INVERSE

INVERSE

valve control

valve control

operation

operation

( Recommended ).

( Recommended ).

700-00028-0, DFC-4 Fan Driver Unit.

Typical characteristic of an inverted pressure control valve This option 

WILL

allow ‘Default-

to-full-fan-speed’ safety operation if the power supply to the controller is removed. 
Recommended Parker valve is the ERA121C30 ( 3000psi operation – other values are 
available, please consult the IHD catalogue ).

Adjustment Guide: 

NON

NON

-

-

INVERSE 

INVERSE 

valve control

valve control

operation.

operation.

Typical characteristic of a normal pressure or flow control valve or variable piston pump 
Electro-hydraulic stroker. This option 

WILL NOT

allow ‘Default-to-full-fan-speed’ operation 

if the power supply to the controller is removed.

Содержание 700-00028-0

Страница 1: ...1 Fan Controller Unit 700 00028 0 Application and Information Manual DFC 4 12 24V Direct Connect option Publ 700 00028 0 ver6 February 2006...

Страница 2: ...and or advice should be sought from your local distributor or from Parker internal sales departments This driver unit has been designed to interface and operate with Wide supply range 10VDC to 32VDC...

Страница 3: ...t under full load 8 Allow wires TO or FROM the unit to short circuit to each other or chassis cabinet e t c 8 Attempt to use this unit in areas of intense RF without adequate screening measures 8 Disc...

Страница 4: ...y slope angle e t c are already calculated for us This means that adjustment of the controller is simple with only three potentiometers Dither frequency which is needed to ensure correct repeatable an...

Страница 5: ...wer supply to the controller is removed Recommended Parker valve is the ERA121C30 3000psi operation other values are available please consult the IHD catalogue Adjustment Guide NON NON INVERSE INVERSE...

Страница 6: ...TE For operational safety if the input PWM signal is below approx 5 the output to the valve is OFF 0 20 40 60 80 100 110 Output Current mA 0 20 30 40 50 60 70 80 100 PWM input 10 90 Output Characteris...

Страница 7: ...ommand Input Value 10V 30V 5 to 95 PWM typical range 10 Command Input Frequency 20 to 125Hz 11 Available adjustments I Max I Min Dither Frequency adjust 12 Dither Frequency coil output Preset to 200Hz...

Страница 8: ...varying the command signal 15 Set command to maximum PWM 16 Isolate the controller from the power Controller 700 00028 0 is now set and ready for operation 17 Attach the lid to the main controller uni...

Страница 9: ...nd signal 16 Set command to minimum PWM 17 Isolate the controller from the power Controller 700 00028 0 is now set and ready for operation 18 Attach the lid to the main controller unit carefully ensur...

Страница 10: ...V max supply input PWM output PWM 0V output Emergency Fan MINIMUM SPEED relay configuration NC NO 1 2 Closing the relay will force the input to 24V supply voltage and the fan will be controlled to ful...

Страница 11: ...ightweight Aluminum alloy Housing Colour Eggshell Black Surface Finish Powder coated Unit size See above size detail drawings Unit Weight Approx 400 grams including Encapsulation material Cable Wire e...

Страница 12: ...12 Parker Hannifin Corporation Fan Drive Systems 14249 Industrial Parkway Marysville OH 43040 Customer Service Department Tel 937 644 4435 Fax 937 642 3639 www parker com hydraulics fandrive...

Отзывы: