background image

3

Product Advantages:

9

Take a few minutes to FULLY read THESE information / data sheets BEFORE starting. 

9

K

eep High Voltage AC cables separate from Low Voltage DC signal and supply cables.

9

M

ake sure the unit supply voltage is the same as the coils on the valve being driven !

9

E

nsure that you are aware of the available adjustments on the electronics and hydraulics. 

9

M

ake sure you have the correct tools to do the intended job ( i.e. D.V.M. ) e.t.c. 

9

Isolate’

this unit from all other equipment 

BEFORE

any  form of welding takes place.

9

C

heck 

ALL

connections to and from this unit to ensure  

NO

short circuits.

9

S

tart’ operating a new system at 

LOW

pressure and with 

SMALL

command signals.

9

C

heck the units supply voltage is 

CORRECT

, ‘

ELECTRICALLY CLEAN

’ and 

STABLE

.

9

O

perate the units within specified operating temperature  for best &  reliable performance.

9

E

nsure that any unused wires / terminals are terminated safely and 

not shorted together

.

9

C

ontact Parker Hannifin sales for more information if you are unsure of connecting this unit.

9

Follow  the set-up procedures in this manual for best  operational results.

ALWAYS

NEVER

8

Arc Weld or Charge Batteries with this driver unit connected as damage can occur.

8

A

ttempt to use this unit if you are unsure of connections or expected operation.  

8

A

ttempt to use this unit in Areas where AC or DC coils 

HAVE NOT 

been fully suppressed.

8

U

se a power supply that is not rated for the correct required O/P current under full load.

8

A

llow  wires TO or FROM the unit to short circuit ( to each other or chassis/cabinet e.t.c. ).

8

A

ttempt to use this unit in areas of intense RF without adequate screening measures.

8

D

isconnect or connect wires to or from this unit unless it it isolated from the power supply.

8

U

se this unit in temperatures that exceed those specified as operation may be effected.

Important Notes:

700-00028-0, DFC-4 Fan Driver Unit.

„

Direct connection to application engine ECU signal ( PWM ). 

„

EMC compliant product to EN50081-1 and EN50082-2 ( heavy industrial ) 

„

1 x proportional MosFet driver output ( PWM ) at upto 1300mA ( @12VDC ).

„

Designed for use in harsh application environments.

„

No extra DIN housing or ‘Card Holder’ to buy.

„

Comes complete with Deutsch sealed connector for fast reliable connection to coil.

„

Product integrity maintained under extreme operational environments.

„

Fully ‘isolated’ design for improved safety and ease of application difficult areas.

„

Self contained driver unit needing only supply power and an external fan speed signal.

„

Unique, Small, light weight unit with ‘Blend-Anywhere’ colour/design.

„

Visible unit status ‘Diagnostic’ LED.

„

Low cost compared to other available modules with comparative functions.

„

Easy to use ‘top entry’ adjustments for all major parameters ( protected under unit lid ).

„

Flame proof resin ‘Encapsulated’ version to suit application environment.

„

Multiturn potentiometers ( 20 turns )  for accurate setting of valve coil parameters.

„

‘Ruggedised’ design allowing use on ‘Internal’ OR ‘External’ applications.

„

Heavy duty cables and connectors for all application environments.

„

Protected inputs and user outputs for maximum reliability and product life.

Содержание 700-00028-0

Страница 1: ...1 Fan Controller Unit 700 00028 0 Application and Information Manual DFC 4 12 24V Direct Connect option Publ 700 00028 0 ver6 February 2006...

Страница 2: ...and or advice should be sought from your local distributor or from Parker internal sales departments This driver unit has been designed to interface and operate with Wide supply range 10VDC to 32VDC...

Страница 3: ...t under full load 8 Allow wires TO or FROM the unit to short circuit to each other or chassis cabinet e t c 8 Attempt to use this unit in areas of intense RF without adequate screening measures 8 Disc...

Страница 4: ...y slope angle e t c are already calculated for us This means that adjustment of the controller is simple with only three potentiometers Dither frequency which is needed to ensure correct repeatable an...

Страница 5: ...wer supply to the controller is removed Recommended Parker valve is the ERA121C30 3000psi operation other values are available please consult the IHD catalogue Adjustment Guide NON NON INVERSE INVERSE...

Страница 6: ...TE For operational safety if the input PWM signal is below approx 5 the output to the valve is OFF 0 20 40 60 80 100 110 Output Current mA 0 20 30 40 50 60 70 80 100 PWM input 10 90 Output Characteris...

Страница 7: ...ommand Input Value 10V 30V 5 to 95 PWM typical range 10 Command Input Frequency 20 to 125Hz 11 Available adjustments I Max I Min Dither Frequency adjust 12 Dither Frequency coil output Preset to 200Hz...

Страница 8: ...varying the command signal 15 Set command to maximum PWM 16 Isolate the controller from the power Controller 700 00028 0 is now set and ready for operation 17 Attach the lid to the main controller uni...

Страница 9: ...nd signal 16 Set command to minimum PWM 17 Isolate the controller from the power Controller 700 00028 0 is now set and ready for operation 18 Attach the lid to the main controller unit carefully ensur...

Страница 10: ...V max supply input PWM output PWM 0V output Emergency Fan MINIMUM SPEED relay configuration NC NO 1 2 Closing the relay will force the input to 24V supply voltage and the fan will be controlled to ful...

Страница 11: ...ightweight Aluminum alloy Housing Colour Eggshell Black Surface Finish Powder coated Unit size See above size detail drawings Unit Weight Approx 400 grams including Encapsulation material Cable Wire e...

Страница 12: ...12 Parker Hannifin Corporation Fan Drive Systems 14249 Industrial Parkway Marysville OH 43040 Customer Service Department Tel 937 644 4435 Fax 937 642 3639 www parker com hydraulics fandrive...

Отзывы: