![Parker 690+ series Скачать руководство пользователя страница 6](http://html2.mh-extra.com/html/parker/690-series/690-series_safety-and-quickstart_3747623006.webp)
English
1-4
Reference
Sequencing
Speed potentiometer across 1(low),
9(high), 2(wiper) OR
External 2-wire speed reference between
1(-) and 2(+)
Jumper 19 and 20 if no external trip contact
Start contact between 12 and 20
Jog contact between 16 and 20
Reverse Direction contact between 15 and 20
Health volt-free contacts between 21 and 22
Running volt-free contacts between 23 and 24
Speed Feedback
•
The Speed Feedback Card is required only for closed
loop Flux Vector Control
•
Install it on the feedback header, shown by the red arrow
in the figure. Ensure a good fit by securely snapping in
place.
•
DIP switches 1,2,3,4 (blue arrow) set the threshold voltage
of the encoder signals. Set all switches to ON (up position)
for complementary encoder signals.
•
Encoder connections to terminal block are:
1 Encoder Supply positive (5–15VDC)
2 Encoder Supply negative (0V)
3 Channel A
4 Channel A complement
5 Channel B
6 Channel B complement
CAUTION
Static Sensitive Board. Install only with
power OFF and follow proper
static/grounding procedures
Содержание 690+ series