Cont.4
Control Options
Requires Power Connections only
Control is via the Keypad
Single Wire Starting
Control Connections
Requires Power Connections and
Control Connections
See Chapter 5 to select Remote
Control is via your control panel
STOP
START
0
100
SPEED
Start
1
2
4
6
7
+10V REF
0V
AIN1
+24V
DIN1
2-position switch
Reference
Speed
LOCAL CONTROL (DEFAULT)
REMOTE CONTROL
PLEASE READ THE MANUAL
Chapters 3 and 4
install and run
the product
details the
Keypad and
menu system
Chapter 5
Chapter 9
technical details
holds many of the
Mounting Options
Cubicle
M1/U
M2/V
M3/W
Motor
Thermistor
(link the terminals
if temperature
sensors not used)
TH1A
TH1B
Power
Supply
Power Connections
L1
N
L1
L2
L3
1
3
Match the motor
voltage to the
drive voltage
Refer to the
motor nameplate
for Star/Delta
voltages
Frame 1
650 Quick Start
Press to enter the menu
and see the first parameter
Press to show the next
parameter
Navigate to the PAR menu
Hold the M key until
Press to edit the
MAX SPEED parameter
Press to exit the parameter
Press (4 times) to show P6
Press to edit the MOTOR
CURRENT parameter
Adjust MOTOR CURRENT
Press to exit the parameter
Adjust MAX SPEED
Press to show P7
Press to edit the BASE
FREQUENCY parameter
Adjust BASE FREQUENCY
Press (3 times) to display
the Local Setpoint
POWER-ON
DIAG is displayed
Quick Set-Up
Refer to motor nameplate
Press to start the
motor and it will ramp
Press to stop the
motor and it will ramp
Press to apply
Local Setpoint
a small setpoint
to the setpoint
to zero
Mount the drive vertically in a lockable cubicle.
Is the drive to operate in Local (using the keypad) or Remote Control?
If Remote Control, make Control Connections.
Make Power Connections. Power-on and follow the Quick Set-Up procedure.
Apply a small setpoint. Start and stop the motor.