6-7
Programming Your Application
650 Series AC Drive
SKIP FREQUENCY
1
This parameter contains the centre frequency of
skip band 1 in Hz
0.0 to 240.0 Hz
0.0
SKIP FREQUENCY
BAND 1
The width of skip band 1 in Hz
0.0 to 60.0 Hz
0.0
SKIP FREQUENCY
2
This parameter contains the centre frequency of
skip band 2 in Hz
0.0 to 240.0 Hz
0.0
SKIP FREQUENCY
BAND 2
The width of skip band 2 in Hz
0.0 to 60.0 Hz
0.0
AUTO RESTART
ATTEMPTS
Determines the number of restarts that will be
permitted before requiring an external fault reset
0 to 10
0
AUTO RESTART
DELAY
Determines the delay between restart attempts for
a trip included in AUTO RESTART TRIGGERS and
AUTO RESTART T. The delay is
measured from all error conditions clearing
0.0 to 600.0 s
10.0
AUTO RESTART
TRIGGERS
Allows Auto Restart to be enabled for a selection of
trip conditions.
Refer to Chapter 6: "Trips and Fault Finding" -
Hexadecimal Representation of Trips
0x0000 to 0xFFFF
0x0000
AUTO RESTART
T
Allows Auto Restart to be enabled for a selection of
trip conditions.
Refer to Chapter 6: "Trips and Fault Finding" -
Hexadecimal Representation of Trips
0x0000 to 0xFFFF
0x0000
LOCAL MIN
SPEED
F
The magnitude of the minimum setpoint that will
be used when running in Local Mode.
0.0 to 100.0 %
0.0 %
ENABLED KEYS
F
The following keys on the 6901 keypad can be
enabled or disabled separately. The combination
produces the parameter setting as in the table
below. The default of FFFF enables all keys.
0000 to FFFF
FFFF
Parameter Setting RUN
L/R
JOG
DIR
0000
0010
0020
0030
0040
0050
0060
0070
0080
0090
00A0
00B0
00C0
00D0
00E0
00F0
-
-
-
-
-
-
-
-
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
ENABLED
-
-
-
-
ENABLED
ENABLED
ENABLED
ENABLED
-
-
-
-
ENABLED
ENABLED
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
-
ENABLED
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
-
ENABLED
6511
When using the standard 6511 and 6521 keypad,
disabling the DIR key prevents the local setpoint
going negative (for reverse). Similarly, disabling
the L/R key prevents the drive being changed from
Local to Remote, or Remote to Local modes.
APPLICATION
LOCK
F
Setting this parameter to TRUE prevents editing of
parameter
P
1.
Set this parameter to FALSE to edit parameter
P
1.
0=FALSE
1=TRUE
0
DETAILED MENUS Selects Full menu detail when TRUE. The additional
parameters in the Full menus are indicated in this
table by
F
0=FALSE
1=TRUE
0
6521
6901
6911
Lefflersgatan 1, SE-754 50 Uppsala, SWEDEN
+46 (0)18-65 70 00
+46 (0)18-10 74 78 [email protected] www.regal.se